SDR DALA2018061103933Battery Pack · inoperativeFWD EMERGENCY LIGHTS INOPERATIVE. REPLACED THE FWD EMERGENCY LIGHT BATTERIES. OP CHECKED GOOD IAW AMM 33-53.SDR DALA2018061103938Line · leakingLEFT HYD QUANTITY DROPPED TO ZERO, FOLLOWED QRH 13.3, ABNORMAL PRESSURE 13.19. ACCORDING TO MCC ADVISORY MESSAGE, AN EMERGENCY LANDING WAS DECLARED. FOUND A LINE LEAKING, FWD SIDE OF LT ENGINE CASE DRAIN FILTER MODULE. REPLACED THE HYD LINE AND FILTERS IAW SDR DALA2018061103937Panel · dislodgedAFT FLT ATTENDANT CALL PANEL DISLODGED DURING LANDING. F/A REPORTED AN ELECTRICAL SHOCK.SDR DALA2018061003921Battery Pack · dischargedEMERGENCY CEILING LIGHTS AT ROW 17-20 INOP. REPLACED BATTERY PACK AT B5-102 REF AMM 33-53. OPS CHECK GOOD.SDR DALA2019102506148Structure · crackedCRACK INDICATION ON RHS VERTICAL STABILIZER NEAR ZFS=52. FOLLOW ON ACTION IS REQUIRED. ERA 569170-14AD ISSUED FOR REPAIR TO CRACK INDICATION ON RHS VERTICAL STABILIZER NEAR ZFS=52. FOLLOW ON ACTION IS REQUIRED. TEMPORARY REPAIR APPROVAL GRANTED FOR 24 MONTHS FSDR DALA2018062604202Unknown · fumesAFTER LANDING AND STARTING THE APU, SMELLED FUMES COMING FROM THE COCKPIT EYE BALL VENTS. WE IMMEDIATELY SHUT THE AIR OFF. APU AND INLET DRY NO SIGNS OF FUEL CONTAMINATION. OPENED APU DOORS VERIFIED NOT CONTAMINATED. CKD FUEL DRAINS, NO FUEL. PRESSURIZED FUESDR DALA2018061003923Battery · intermittentSEVERAL OVHD EMER LIGHTS INOP SEAT ROWS 11-16. REMOVED SEVERAL CEILING PANELS TO ACCESS WIRING. FOUND BATTERY PACKS INTERMITTENT. NEEDS BATTERIES(907305). RPLD BATTERIES PER AMM 33-53. ALL EMER LIGHTS NOW CK GOOD. OK FOR SERVICE. REINSTALLED CEILING PANELS.SDR DALA2018061003920Smoke Detector · brokenLAVATORY SMOKE DETECTOR WILL NOT TURN OFF, LOCATIONS:203. R&R SMOKE DETECTOR DUE TO BROKEN BASE. REF AMM 26-17. OPS CKS GOOD.SDR DALA2018061203951Panel · crackedPERFORM GVI OF RT WING UPPER SURFACE. DUE TO PASSENGER REPORT OF A CRACK ON THE RT WING UPPER SURFACE AS OBSERVED FROM THE CABIN, PLEASE SET- UP TO PERFORM A GVI OF THE RT WING UPPER SURFACE FOR ANY SIGNS OF A CRACK. WHILE WORKING MD LOG 0592224 FOR POSSIBLE SDR DALA2018061003924Power Supply · inoperativeUPON SVC CK FOUND ROWS 1 CD THRU 12 ED EMERGENCY PATH LIGHTING INOP. R&R BATTERY POWER SUPPLY FWD CABIN PER WDM 33-51-12. ALSO R&R BATTERY ASSY (FWD CABIN) PER 33-53 OPS CKS NML A/C OK FOR SERVICE.SDR DALA2018061003922Wire · brokenFOUND EMER LIGHTS AT SEAT ROWS 11,19,29 INOP. RELAMPED SEATS , NO HELP. FOUND SEAT ROWS 11 AND 29 WIRES BROKEN AT DISCONNECT. RETERMINATED SAME. SEAT HARNESS AT ROW 19 DAMAGED. REPLACED HARNESS. OPS CKS GOOD PER SWPM CHAP 20.SDR DALA2018061003919Aileron · delaminatedRT AILERON LWR TRAILING EDGE DELAMINATION. RIGHT AILERON P/N 5955401-502, S/N 754 REMOVED REF W/C 2710-4124-RH. RIGHT AILERON P/N 5955401-502, S/N 409 INSTALLED PER W/C 2710-4124-RH.SDR DALA2018060803885Battery Pack · no testFAILED EMERGENCY LIGHT BATTERY PACK AT BS 1338. THE BATTERY PACK WAS REPLACED IAW AMM 33-53-00. OPS TESTED GOOD IAW AMM 33-53-00.SDR DALA2018060703863Cable · out of positionTAILCONE UNSAFE MESSAGE. FOUND INTERIOR CABLE DISCONNECTED, OUT OF RETAINING MECHANISM. SECURED THE CABLE AND PERFORMED ODI TEST IAW AMM 53-53-00. OPS NORMAL ACFT OK FOR SERVICE. THE TAILCONE SLIDE REARMED. INSPECTION AND RIGGING OK IAW AMM 53-53.SDR DALA2018060763862Screw · out of toleranceDURING A HORIZONTAL STABILIZER ACTUATOR ASSEMBLY END PLAY CHECK, THE FINAL END PLAY READ MORE THAN 0.040 INCH. SCREW AND NUT WERE REMOVED AND REPLACED IAW AMM 27-40-01-401, AND AMDS 2742-4520.SDR DALA2018060653843Battery · dischargedFLT ATTENDANTS REPORT A CHIRPING SOUND, INTERMITTENTLY FROM AFT RIGHT LAVATORY. REPLACED THE AFT RIGHT LAVATORY SMOKE DETECTOR BATTERY IAW AMM 26-13. OPS CHECKED GOOD.SDR DALA2018060603841Channel · crackedA CRACKED AFT CHANNEL, ON THE FWD RT MLG WW DOOR FRAME BS 937, RBL 55. THE CHANNEL WAS REPLACED IAW SRM 51-30-02, AND SRM 51-30-05.SDR DALA2018060503809Smoke Detector · faultyAFT LEFT LAVATORY SMOKE DETECTOR SOUNDING UPON ARRIVAL IN ATL. NO SMOKE FOUND. REPLACED AFT LEFT SMOKE DETECTOR PER AMM 26-21.SDR DALA2018060503808Support Fitting · damagedRT MLG RETRACT MECHANISM SUPPORT FITTING BUSHINGS DAMAGED AND PIN WORN. REPLACED RT MLG RETRACT MECHANISM SUPPORT FITTING PER AMM 57-40-02.SDR DALA2018062604203Unknown · odorON SHORT APPROACH AT 800 AGL, A VERY STRONG, ACRID, ELECTRICAL SMELL IN COCKPIT. NO VISIBLE SMOKE. FLIGHT ATTENDANTS SMELLED NOTHING. VERY SLOW TO DISSIPATE AT GATE. PERFORMED PNEUMATIC DIST CABIN SMOKE/ODOR TROUBLESHOOTING W/C 2120-2367 PER NO-DO ODI PROCEDURSDR DALA2018060403810Coupling · looseEMERGENCY DECLARED. AIRCRAFT DIVERTED TO TLH DUE TO ODOR NEAR ROW 35. THE ODOR PERSISTED UNTIL ENGINE SHUTDOWN. AN OVERWEIGHT LANDING WAS PERFORMED. MAINTENANCE FOUND THE APU INLET WET WITH HYDRAULIC FLUID AND A HYDRAULIC LEAK IN LEFT WHEEL WELL AT A COUPLINGSDR DALA2018060403780Door Frame · wornWEAR ON LOWER SKIN OF RT/FWD OVERWING EMERGENCY EXIT DOOR JAMB. IN REF NRC 00086 WEAR ON LOWER SKIN OF RT/FWD OVERWING EMERGENCY EXIT DOOR JAMB WAS REPAIRED PER ETI-88-17-054 REV 4 AND ER/A 569086-14 REV ORG.SDR DALA2018060403775Door Frame · wornWEAR ON LOWER SKIN OF RT/FWD OVERWING EMERGENCY EXIT DOOR JAMB. WEAR ON LOWER SKIN OF RT/FWD OVERWING EMERGENCY EXIT DOOR JAMB WAS REPAIRED PER ETI-88-17-054 REV 4 AND ER/A 569086-14 REV ORG.SDR DALA2018060403779Door Frame · wornWEAR ON LOWER SKIN OF RT/FWD OVERWING EMERGENCY EXIT DOOR JAMB. IN REF NRC 00086. WEAR ON LOWER SKIN OF RT/FWD OVERWING EMERGENCY EXIT DOOR JAMB WAS REPAIRED PER ETI-88-17-054 REV 4 AND ER/A 569086-14 REV ORG. PERFORM GENERAL VISUAL INSPECTION OF THE SECTION ISDR DALA2018060403778Door Frame · corrodedCORROSION ON AFT CARGO COMPARTMENT DOOR JAMB. CORROSION LEVEL 2. CORROSION ON AFT CARGO COMPARTMENT DOOR JAMB WAS REPAIRED PER SRM 53-05 FIG 123. AREA WITHIN LIMITS WAS ATTENDED WITH NRC 00211.SDR DALA2018060403777Skin · corrodedFUSELAGE LAV SVC CUTOUT STA 1322 AT L-22L CORROSION. COMPLIED WITH ERA 568960-14 REV B SECTION 1 PERMANENT REPAIR. ALL STEPS IN PRI'S 568960-14 REV O, REV 1, REV 2, REV 3, AND REV 4 MATCH STEPS IN ERA 568960-14 REV B SECTION 1 PERMANENT REPAIR.SDR DALA2018060403776Mechanism · out of adjustTAILCONE RELEASE MECHANISM CAM FAILED TORQUE CHECK. ADJUSTED CAM MECHANISM W/REF TO AMM 53-53-02.SDR DALA2018060403774Light · inoperativeSEAT 19 EMERGENCY LIGHT NOT WORKING. REMOVED AND REPLACED EMERGENCY LIGHT ON SEAT 19 REF AMM 33-53 OPS CHECK GOOD.SDR DALA2018060403781Smoke Detector · dirtyIN FLIGHT FA REPORTED THAT FWD LAV SMOKE DETECTOR BEEPED FOR ABOUT 20 SECONDS. NO SMOKE FUMES NOTED. FOUND COPIOUS AMOUNTS OF DUST & DEBRIS ON TOP OF SMOKE DETECTOR. REMOVED & REPLACED FWD LAV SMOKE DETECTOR. OK FOR SVC PER MD88 AMM 26-13.SDR DALA2018060103747Floor Panel · delaminatedFLOOR PANEL 693C DELAMINATED AT AFT END. THE FLOOR PANEL WAS REPLACED IAW AMM. 53-20-01-201.SDR DALA2018053103718Cable · deterioratedKEVLAR CABLE FOUND DETERIORATED BE LT GROMMET. R/I KEVLAR CABLE PER MD88 AMM 53-53 & WORKCARD 5350-01077-0101 STEP 14. (LP4247373)SDR DALA2018052903617Pin · missingFOUND THE R1 SLIDE ENGAGEMENT PIN MISSING. R & R THE R1 DOOR SLIDE IAW AMM 2561-4964.SDR DALA2018052903616Lamp · inoperativeEMERGENCY LIGHTS WERE INOPERATIVE AT 1CD. REPLACED THE LAMP. OPS CHECKED GOOD.SDR DALA2018052803607Battery · dischargedFWD EMERGENCY LIGHTS INOP. REPLACED BATTERIES IAW AMM 33-53 OP CHECK GOOD.SDR DALA2018052903614Frame · crackedFOUND THE RT WHEEL WELL CUTOUT CRACKED. REMOVED AND REPLACED THE FRAME IAW ERA 568949-14, SECTION 2, DWG 590584, AND ERA 568949-14, SECTION 2.SDR DALA2018052703604Fuse · blownEMERGENCY LIGHTS FROM SEAT 31 AFT INOPERATIVE. REPLACED FUSES IN CHARGER PER CMM 25-60-03. OPS CHECK GOOD PER MD88 AMM 33-53.SDR DALA2018052503603Battery · dischargedCEILING EMER LIGHTS AT ROWS 26-31 INOP. REPLACED BATTERIES AT PACK B5-106. OPS CK OK.SDR DALA2018052503605Engine · making metalFLT 1668 DIVERTED TO CAE DUE TO A RIGHT ENGINE COMPRESSOR STALL ON CLIMB OUT AND ERRATIC ENGINE INDICATIONS. THE FLIGHT CREW DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. THE ENGINE WAS NOT SHUT DOWN. MAINTENANCE FOUND METAL IN THE TAIL PIPE AND THE 3RD &SDR DALA2018052503602Battery · dischargedON SERVICE CHECK- EMERGENCY LIGHTS AT L1, R1, AND COCKPIT OVERHEAD DID NOT REMAIN ON. REPLACED EMERGENCY LIGHT BATTERIES IN FWD DROP DOWN PNL. OPS CHECKS GOOD AMM 33-53.SDR DALA2018052403541Engine · failedAT 27,000 FT LEFT ENGINE PRODUCED A LOUD BANG AND IMMEDIATELY FOLLOWING THE EPR, N1, N2 ROLLED BACK TO IDLE. WE CONDUCTED THE ENGINE SEVERE DAMAGE QRH AND LANDED WITH THE LEFT ENGINE AT IDLE. THE RIGHT ENGINE NEVER EXCEEDED ANY LIMITS DURING THE FAILURE. REF SDR DALA2018052403540Wire · brokenEMERG LIGHT ON CATWALK INOP DUE TO BROKEN WIRE. RETERMINATED WIRE PER SPWM CH 20 CKS GOOD.SDR DALA2018052403539Light · inoperativeLT FWD OVERWING EMER EXIT 1 BULB INOP. REPLACED LT FWD OVERWING EMER EXIT BULB PER AMM 33-50. OPS CHECK GOOD AT THIS TIME.SDR DALA2018052403538Light · inoperativeDOOR R1 EMERGENCY LIGHT INOP. RELAMPED OPS CHECK GOOD IAW AMM 33-51.SDR DALA2018052403537Charger · inoperativeON SVC CK FOUND FIST CLASS EMERGENCY LIGHTS INOP. R&R FUSE AT BATTERY CHARGER IN O/H COMP ABOVE 2 CD PER WDM 33-51 AND OPS CK PER AMM 33-53 OPS CK GOOD.SDR DALA2018052303512Cable · brokenTAIL CONE INADVERTENTLY DROPPED AND THE SLIDE RAFT DID NOT INFLATE. FOUND CABLE ASSY TAIL CONE JETTISON BROKE, REMOVED BROKEN CABLE 1/2 FROM A/C TAIL CONE RELEASE SYS FUNCTION CHK ACCOMPLISHED ON TASK CARD 5350-01077-0101 CARD 7037790.SDR DALA2018052203497Skin · corrodedAFT LAVATORY SERVICE PANEL LOWER FWD CORNER, IS SUSPECTED OF BEING CORRODED. REPAIRED IAW ERA 568545-14 REV. A.SDR DALA2018052203496Lanyard · wornWORN SLIDE LANDYARD ATTACHED AT THE TAILCONE. THE LANDYARD WAS REPLACED IAW AMM 53-53-00.SDR DALA2018052203495Skin · corrodedFUSELAGE SKIN BULGING AT THE BOTTOM END OF THE AFT LAVATORY SERVICE PANEL CUTOUT. POSSIBLE EVIDENCE OF CORROSION.SDR DALA2018052203494Skin · corrodedTHE FUSELAGE LAVATORY SERVICE CUTOUT SKIN, BS 1322, LONGERON 22L FOUND CORRODED. COMPLIED WITH STEPS 1 THROUGH 23 OF PRI 568545-14, REV. 5. STEPS 1 THROUGH 23 OF ERA 568545-14 REV A. MATCH THOSE OF PRI 568545-14, REV. 5. ERA 568545-14 REV. A COMPLIED WITH.SDR DALA2018052103493Wire Harness · brokenSEAT 30DE EMERGENCY LIGHT INOPERATIVE. FOUND THE WIRE HARNESS BROKEN UNDER THE SEAT. R & R THE WIRE HARNESS IAW AMM 33-53. OPS CHECKED GOOD.
Back to Mcdonnell Douglas MD-88