Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2018011700260Reservoir · malfunctionedDURING CRUISE, RT HYD LOW PRESSURE MESSAGE ON OAP, RIGHT HYD QTY WENT UP TO 19 QTS. FOLLOWING QRH, REPRESSURIZED BELOW 10,000 FT. PRESSURE CAME UP TO 3000 PSI, QTY DOWN TO 10 QUARTS. PRESSURE WAS ZERO FOR 5 - 20 MINUTES. REPLACED THE RESERVOIR AND ENGINE DRIVSDR DALA2018011700258Controller · faultedLOST PRESSURIZATION AT FL 310 BOTH AC PACKS IN AUTO. BOTH 1 AND 2 AUTO PRESSURE CONTROLLERS SHOWED "INOP" ANNUNCIATION. PERFORMED AUTO PRESS CONTROLLER BITE. FOUND BOTH CONTROLLERS FAULTED. RESET CONTROLLERS. AIRCRAFT WAS RETURNED TO SERVICE.SDR DALA2018011700259Light · inoperativeON APPR WHEN LANDING GEAR DOWN, NO GREEN GEAR INDICATOR ON NOSE GEAR. RELAMPED NOSE GEAR DOWN INDICATION LAMPS. OPS CK NML. C/W NO GO ODI PREVENTION REF AMM 32-60-00-101 OK FOR SVC.SDR DALA2018011700256Pin · looseFOUND L1 DOOR SLIDE ENGAGEMENT PIN LOOSE/OUT. R&R L1 DOOR SLIDE PER W/C 2561-4964.SDR DALA2018011700255Door Frame · crackedCRACK IN FWD ACCESSORY COMPARTMENT DOOR JAMB. FWD ACCESSORY COMPARTMENT DOOR JAMB WAS REPAIR AS A PERMANENT REPAIR PER ER/A 564870-14 REV ORIGINAL AND ETI-88-18-001 REV 2.SDR DALA2018011700254Smoke Detector · missingFOUND RT AFT LAV MISSING SINGLE STATION SMOKE ALARM. REPLACED MISSING RT AFT LAV SMOKE DETECTOR IN REF WITH AMM 26-13. TESTS GOOD. OK FOR SERVICE.SDR DALA2018011700253Door · crackedFOUND 1.5" CRACK ON FWD B/B DOOR LOWER FWD CORNER. FABRICATED AND INSTALLED NEW REPAIR DOUBLER PER ERA 486624-14MA REV 0.SDR DALA2018011500242Frame · crackedCRACK ON FRAME BS 1485 , LONGERON 24R. REPAIRED IAW SRM 53-03, FIG 43.SDR DALA2018011500241Skin · corrodedCORROSION ON BARREL NUT HOLE NR 1 IN SKIN AT LT SIDE OF HORIZONTAL STABILIZER. REPAIRED IAW ETI-88-17- 238 REV.1 AND ER/A 562431-14 AD REV A.SDR DALA2018011700257Unknown · odorDUE TO REPORT OF BURNING RUBBER SMELL ON TAKE OFF. PER CREW VERBAL, ALL ENG. INDICATIONS NORMAL. CLOSE VISUAL INSP OF WHEEL WELLS, LOWER AFT FUSELAGE, APU INLET AND BOTH ENGINES REVEALED NO FLUID CONTAMINATION.SDR DALA2018011200240Wire · damagedDURING SERVICE CHECK, FOUND EMERGENCY LIGHTS BROKEN AT 34DE. REPAIRED WIRING. REPLACED THE POWER SUPPLY. OPS CHECKED GOOD.SDR DALA2018011200224Battery Pack · dischargedOVERWING EMERGENCY LIGHT INOP. T/S, R&R OVERWING EMERGENCY EVACUATION LIGHT BATTERY PACK PER MM 33-53. OPS CHK - GOOD. OK FOR SVC.SDR DALA2018011200223Door Frame · crackedCRACK ON CORNER UP SIDE OF DOOR JAMB FWD WHEEL WELL LT. DOOR JAMB FWD WHEEL WELL LT ( PAN ) WAS REPLACED PER DC9/MD80 SRM 51-30-2 AND 51-30-5.SDR DALA2018011200222Support · crackedCRACKED WATER TANK SUPPORT STA Y=522 X=-43 Z=-7 AT CENTER CARGO COMPARTMENT (RT TUNNEL) (C2). CRACKED WATER TANK SUPPORT STA Y=522 X =-43 Z=-7 AT CENTER CARGO COMPARTMENT WAS REPLACED PER ETI-88-18-002 REV 1 AND ERA:564881-14 REV ORIGINAL.SDR JR2R20180111006Fitting · crackedLOUVER FITTING CRACKED AT FRAME BS 1463, LONGERON 8L. REMOVED AND REPLACED THE FITTING IAW SRM 51-30-5, 51-10-4, AND 51-10-3.SDR JR2R20180111004Fitting · brokenLOUVER FITTING BROKEN AT FRAME BS 1463, LONGERON 4L. REMOVED AND REPLACED THE FITTING IAW SRM 51-30-5, 51-10-4, AND 51-10-3.SDR JR2R20181011005Angle · brokenLOUVER CLIP BROKEN, CANTED FRAME BS 1463, LONGERON 4R. REMOVED AND REPLACED IAW SRM 51-30-5, 51-10-4, AND 51-10-3.SDR JR2R20180111007Attach Angle · crackedLEFT WINDAGE TRAY ATTACH ANGLE CRACKED. REMOVED AND REPLACED THE ATTACH ANGLE IAW SRM 51-30-2, 51-30-5, 51-10-2, AND 51-10-4.SDR DALA2018011200220Connector · defectiveDURING SVC CHECK FOUND EMERGENCY LIGHTS ON SEAT 3CD AND 22ED INOP. REPINNED CONNECTORS AND OPS CHECKED IAW MD88 AMM 33-53.SDR DALA2018011100193Unknown · malfunctionedWHILE TAXIING IN AND MAKING LEFT TURN ON TAXIWAY Z THE RIGHT BRAKE SEEMED TO LOCK UP AND PULL AIRCRAFT TOWARDS EDGE OF TAXIWAY AIRPLANE DEPARTED TAXIWAY AND HIT 2-3 TAXI LIGHTS. INSPECTED A/C PER AMM 05-51-03 NO DAMAGE FOUND. JACKED RT GEAR AND CYCLED BRAKES SSDR DALA2018011100192Door Frame · crackedCRACK ON CORNER UP SIDE OF DOOR JAMB FWD WHEEL WELL RT. DOOR JAMB FWD WHEEL WELL RT ( PAN ) WAS REPLACED PER SRM 51-30-02 AND 51-30-05.SDR DALA2018011100191Beam · crackedDURING C1 DOOR PAN DISASSEMBLY, CRACK WAS FOUND ON BEAM NR 5 FWD EDGE IN REF NRC 00240. CRACKS UPPER FWD EDGE PAN AND BEAM NR 5 WERE REPAIRED PER ETI-88-17-248 REV 3 AND ER/A:564810-14 REVISION ORIGINAL.SDR DALA2018011000172Access Panel · corrodedCORROSION ON RH/LH FUEL ACCESS PLATES NBR 1409C AND 1303C AT RH AND LH WING. (AD). LEVEL CORROSION 2: ACCESS PLATES NBR 1303C AND 1409C BLEND OUT REPAIR IS NOT PERMITTED ON THE UPPER WING ACCESS DOOR (P/N 3912757) DUE
TO THE REDUCED AREA OF THE CONDUCTIVE INTSDR DALA2018011100194Smoke Detector · faultyMOMENTARY ALARM AFT LEFT LAV NO SMOKE SMELLED QUIT AFTER A BIT. R&R SMOKE DET AND BATTERY. OPS CKS GOOD.SDR DALA2018011100190Control Quadrant · crackedDURING REMOVAL OF CAPT'S RUDDER PEDAL BRACKET, FOUND RUDDER PEDAL ADJUSTMENT QUADRANT CRACKED. RMVD AND REPL CAPT'S RUDDER PEDAL ADJUSTMENT QUADRANT PER AMM 27-20(134146). C/W RII INSTALL OF RUDDER PEDAL ADJ QUADRANT PER AMM 27-20.SDR DALA2018011100189Bracket · crackedWHILE PERFORMING HFEC INSPECTION OF CAPTAINS RUDDER PEDAL BRACKET PER EM2720-01088-0901, FOUND CRACK IN AFT OUTBOARD WEB RADIUS. MARKED. CAPTAINS RUDDER PEDAL BRACKET REPLACED IAW AMDS W/C 2720-01088-0701.SDR DALA2018011000171Frame · crackedCRACKED FRAME ON STA Y= 1510 CANT AT 3 AND 5 HRS POSITION, AFT ACCESSORIES COMPARTMENT. FRAME ON STA Y=1510 CANT WAS REPLACED PER SRM 51-30-2.SDR DALA2018011000170Tie Down · corrodedINITIAL INSPECTION: CORROSION ON TIE TRACKS LH/RH FROM STA Y=1003 TO STA Y=1155 AT AFT CARGO COMPARTMENT. CORROSION LEVEL II. TIE TRACKS LH/RH FROM STA Y=1003 TO STA Y=1155 AT AFT CARGO COMPARTMENT WERE REPLACED PER
DC-9/MD-80 SRM 51-30-2 AND SRM 51-30-1. (LSDR DALA2018010900173Engine · making metalATB/IFSD - RETURNED TO ATL DUE TO RIGHT ENGINE COMPRESSOR STALLS WITH VIBRATIONS AT TOP OF CLIMB. PULLED THE ENGINE BACK TO IDLE. CREW FOLLOWED QRH AND SHUT DOWN ENGINE DUE TO VIBRATIONS. EMERGENCY DECLARED. MAINTENANCE FOUND METAL IN TAIL PIPE AND TURBINE DASDR DALA2018010800126Lamp · inoperativeSEAT 31ED EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-00, OPS CHECKED GOOD.SDR DALA2018010800124Engine · failedRETURNED TO DEPARTURE DUE TO RIGHT ENGINE COMPRESSOR STALLS WITH VIBRATIONS AT TOP OF CLIMB. PULLED THE ENGINE BACK TO IDLE. CREW FOLLOWED QRH AND SHUT DOWN ENGINE DUE TO VIBRATIONS. CORRECTIVE ACTION: MAINTENANCE FOUND METAL IN TAIL PIPE AND TURBINE DAMAGE. SDR DALA2018010800123Connector · damagedEMERGENCY SEAT MOUNTED LIGHTING DAMAGED AND INOPERATIVE. PINNED EMERGENCY LIGHT.SDR DALA2018010800122Battery Pack · inoperativeFWD AND ENTRANCE AND COCKPIT EMERGENCY LTS INOPERATIVE. REPLACED TWO BATTERIES ON THE EMERGENCY LIGHT.SDR DALA2018010800121Cargo Track · corrodedCORROSION ON CARGO TRACKS, BS 1155 TO 1322 IN THE AFT CARGO BAY. THE CARGO TRACKS WERE REPLACED.SDR DALA2018010700113Angle · crackedCRACKED ANGLE AT THE R1 DOOR INSTERNAL STRUCTURE, A NEW ANGLE WAS FABRICATED IAW DWG 9911579, REV L AND REPLACED IAW SRM 51-30-4 , 51-30-5.SDR DALA2018010700112Longeron · corrodedCORROSION OUT LIMITS ON LONGERON 28L, BS 1338. THE LONGERON WAS REPAIRED IAW SRM 53-02, FIG 18.SDR DALA2018010700110Angle · corrodedCORROSION ON VERTICAL ANGLE BS 1309, LONGERON 23L IN THE AFT CARGO BAY. THE VERTICAL ANGLE WAS REPLACED IAW SRM 51-30-2, 51-30-1, AND DWG 5936661, REV BC.SDR DALA2018010700109Intercostal · corrodedCORROSION OUT OF LIMITS ON INTERCOSTAL BETWEEN BS 1309 - 1322, LONGERON 28L IN THE AFT CARGO BAY. THE INTERCOSTAL WAS REPAIRED IAW SRM 53-01, FIG 2.SDR DALA2018010700125Battery Pack · inoperativeFWD EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED THE BATTERIES.SDR DALA2018010700111Web · crackedCORROSION AND A CRACK WAS FOUND ON THE WEB BS 1212 TO 1222, LONGERON 27R. THE WEB WAS REPAIRED IAW SRM 53-01, FIG 2, SHEET 3.SDR DALA2018010500087Wire · brokenSEAT 14DEF IN SEAT EMERGENCY LIGHT INOP. FOUND WIRE BROKEN AT SEAT HARNESS. REPAIRED PER ESPM 20-90. CHECKS GOOD.SDR DALA2018010500089Acm · failedFLOW LIGHT ILLUMINATED, BOTH PACKS TRIPPED. EMERGENCY DECLARED WITH ACCOMPANYING DESCENT TO 10K FEET WHERE PACKS WERE RESET AND PRESSURIZATION REGAINED. OXYGEN MASKS DID NOT DROP. REPLACED MULTIPLE TEMP AND FLOW CONTROL REGULATING COMPONENTS INCLUDING RT ACM SDR DALA2018010500088Fitting · corrodedCORROSION OUT LIMITS ON FRAME CLIP STA Y=1231 BTW LONG 30 AND 29R AT AFT CARGO COMPARTMENT. LEVEL CORROSION 2. FRAME CLIP STA Y=1231 BTW LONG 30 AND 29R AT AFT CARGO COMPARTMENT WAS REPLACED PER SRM 51-10-4, 51-30-2 AND 51-30-5.SDR DALA2018010500086Battery · dischargedEMERGENCY LIGHTS INOP FWD DOOR'S. REPLACED BATT, OPS NOW OK PER AMM 33-53.SDR DALA2018010500085Floor Support · corrodedCORROSION ON FLOOR SUPPORT STA Y= 788 BTW LONG 24L AND LONG 24R AT MID CARGO COMPARTMENT. (LEVEL CORROSION 2) FLOOR SUPPORT STA Y=788 WAS REPAIRED PER SRM 53-01 FIG 2.SDR DALA2018010500084Skin · dentedRE-EVALUATE DENT STA 1290-1338 ACROSS L-22R. DAMAGE AREA WAS REPAIRED PER ETI 88-17-241 REV 4 AND ER/A 494621-14 REV "B" SECTION III.SDR DALA2018010500083Light · inoperativeSEAT 23D EMERGENCY LIGHT IS OUT. RELAMPED EMERGENCY LIGHT AT 23D OPS CHECK GOOD.SDR DALA2018010500082Angle · crackedDURING DISASSEMBLY PARTS OF CARGO DOOR (C1), CRACK WAS FOUND ON ANGLE T IN REF NRC 00240. ANGLE T WAS REPLACED PER SRM 51-30-2, 51-30-4 AND DWG 9957663 REV W.SDR DALA2018010500080Pan · crackedCRACK ON PAN UNDER STOPS FITTINGS 2,4 FWD AND 4, AND 5 AFT ON FWD CARGO DOOR. THE PAN WAS REPAIRED IAW ETI-88-17-245, REV. 3 AND ERA 564546-14 REV. ORIGINAL. STOP NR 4 WAS REPAIRED IAW SRM 52-05, FIG 50, AND STOP NR 5 WAS REPAIRED IAW SRM 52-03 D FIG.10.SDR DALA2018010400067Warning System · false activationDIV TO MSP DUE TO RIGHT MAIN LANDING GEAR UNSAFE LIGHT WITH GEAR UP. NO FAULTS ON PSEU. NO DISCREPANCIES NOTED ON GEAR SWING. NO OTHER DISCREPANCIES NOTED AFTER DETAILED INSPECTION. REPLACED RT RETRACT ACTUATOR PRECAUTIONARY.
Back to Mcdonnell Douglas MD-88