Mcdonnell Douglas MD-88
Service difficulty reports · 21,991
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD88' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019101105833Connector · dirtyTAILCONE UNSAFE ILLUMINATED IN FLIGHT. 53. INSPECTED TAILCONE CABLES AND SWITCHES. CLEANED CONNECTOR PLUGS FOR INDICATIONS SWITCHES. INDICATION NOW NORMAL. OK FOR SERVICE. (LP6205584)SDR DALA2019101105832Mechanism · not seated"TAILCONE UNSAFE" ILLUMINATED INFLIGHT. FOUND RELEASE MECH UNSEATED FROM CLIPS. ALLOWED LOCK CABLE TO SWITCH TO COME LOOSE. RESEATED LOCK CABLE TO SWITCH & INSTALLED MECH IN CLIPS. VERIFIED TAILCONE UNSAFE LIGHT OUT PER MD88 AMM 53-53. J DAVIS 311408 VERIFIED SDR DALA2019100405681Smoke Detector · malfunctionedAFT LT LAVATORY SMOKE DETECTOR CHIRPING. REMOVED AND REPLACED THE SMOKE DETECTOR, OPS CHECKED NORMAL, OK FOR SERVICE.SDR DALA2019100305657Battery Pack · inoperativeCABIN AND BOTH FWD ENTRANCES EMERGENCY LIGHTS AT L2-175, L2-152 AND L2-155 INOP. REPLACED BATTERIES IN POWER SUPPLY PACK AT B5-23 PER MD88 AMM 33-53. OPS CHKS GOOD, A/C OK FOR SVC. (LP6216345)SDR DALA2019100205645Battery Pack · inoperativeEMERGENCY LIGHTS AT L1, R1 AND CO INOP. R/R BATTERIES AT BATERY PACK B5211 IAW MM 33-53.SDR DALA2019093005575Access Door · brokenON WALK AROUND FOUND STARTER ACCESS DOOR BROKEN OFF ON #2 ENG. R+R STARTER ACESS DOOR REF MD88 AMM 71-10 OK FOR SVC. (LP5587208)SDR DALA2019093005574Pin · disengagedSVC CHK FOUND L1 DOOR SLIDE PIN NOT ENGAGED. REMOVED L1 DOOR SLIDE REF W/C 2561-4964 INSTALLING NEW SLIDE REF W/C 2561-4964. SLIDE, EVAC, FO OFF 88-2560-9-0003 S/N 03040. (LP5587108)SDR DALA2019093005577Lens · missingLEFT WING AFT POSITION LIGHT LENS COVER MISSING. INSTALLED LENS COVER ASSY PER MD 88 AMM 33-43. OK FOR SVC. (LP5992756)SDR DALA2019100305658Door · detachedEXTERNAL POWER DOOR MISSING. INSTALLED EXTERNAL POWER ACCESS DOOR ASSYM PER MD88 CMM 53-30-02.SDR DALA2019092905576Apu · odor"NO GO" ODI PREVENTION - DRIVER DO NOT DISPATCH THE AIRCRAFT" - W/O MCC APPROVAL" - ON TAXI OUT APU AUTO S/D THEN PASS NOTED A ODD SMOKE/SMELL IN THE CABIN. CREW ALSO NOTED WEIRD SMELL BUT ATTRIBUTED TO THE APU S/D. C/W AMDS CARD 2120-2367 PER NO GO ODI PREVENSDR DALA2019092705558Terminal · out of adjustUPON ACTIVATION OF NOSE LANDING LIGHT, ON FINAL APPROACH, GOT SPARK BECAUSE OF ELECTRICAL SHORT. FOUND 2 WIRE TERMINALS CONTACTING EACH OTHER ON NOSE LANDING LIGHT SWITCH. REPOSITIONED TERMINALS PER SWPM 20-20. OPS CHECK GOOD.SDR DALA2019092705557Battery Pack · dischargedFIRST CLASS EMERGENCY LIGHTS INOP. REPLACED B5-211 BATTERY PACK AND POWER SUPPLY AT STA 388R IAW AMM 33-53 - ALL CKS GOOD.SDR DALA2019092605518Smoke Detector · faultyLEFT AFT LAVATORY SMOKE DETECTOR CONTINUOUSLY SOUNDING. REM+REPL LT AFT LAV SMOKE DETECTOR PER AMM 26-13. OPS CK OK. (LP5595596)SDR DALA2019092605517Light · inoperativeSEAT ROW 21 EMERG LIGHT INOP. RPLCD EMERGENCY LIGHT AT SEAT ROW 21. REF AMM 33-52. CKS GOOD. (LP6406723)SDR DALA2019092605516Wire Harness · defectiveEMERGENCY LIGHT AT 30ED INOP. R&R HARNESS OPS NML REF AMM 33-52. (LP5596570)SDR DALA2019092505495Smoke Detector · malfunctionedAFT RT LAV SMOKE DETECTOR CHIRPING. R/R AFT RT LAV SMOKE DETECTOR - REF AMM 2617. (LP6040676)SDR DALA2019092305437Fluid · leakingDURING INTIAL BOARDING NOTICED BURNING OIL ODOR ON FLT DECK, SHUT OFF PACKS ODOR DISSIPATED. SHUT APU DOWN AND FOUND OIL OR HYD FLUID BACK FLOWING OUT OF APU NON RAM DOOR. REVIEWED SMOKE/FUME QUESTIONNAIRE. PERFORMED TROUBLESHOOTING PER WORKCARD 2120-2367. PERSDR DALA2019101105834Cable · dislodgedTAILCONE UNSAFE ON OAP. FOUND LOCKING CABLE DISLODGED FROM SWITCH AND PLACARD TORN. VERIFIED TAILCONE IS PROPERLY LOCKED IN PLACE, SECURED LOCKING CABLE, CHECKED TAILCONE CAM MECHANISM AND REPLACED INTERNAL DECAL. TAILCONE CHECKS NRML PER MD 88 AMM 53-53. (LP5SDR DALA2019092205436Unknown · smokeCOMING THROUGH 12,000 ON DESCENT FA CALLED US TO NOTIFY US THERE WAS A SMELL OF SMOKE IN THE FIRST CLASS CABIN. WE IMMEDIATELY COULD SMELL THE SMOKE AS WELL. THE FA ALSO SAID THERE WAS A SLIGHT HAZE IN THE 1ST CLASS CABIN AREA. THE SMOKE DISSIPATED A FEW MINUTSDR DALA2019092005428Light · inoperativeEMER SEAT LIGHT AT 14E INOP. RELAMPED SEAT 14E EMER SEAT LIGHT. OPS CK'D GOOD. (LP6122470)SDR DALA2019091905418Smoke Detector · malfunctionedLAVATORY SMOKE DETECTOR WILL NOT TURN OFF. LOCATIONS 201. R/R LAV SMOKE DETECTOR PER AMM 26-17, OPS CHECK GOOD. (LP1277573)SDR DALA2019091705362Line · looseNR 1 ENGINE PYLON FIRE SUPPRESSION LINE LOOSE @ PYLON. TIGHTENED FIRE SUPPRESSION LINE @ PYLON PER AMM 20-30. (LP1275066)SDR DALA2019091705361Battery Pack · dischargedFWD OVERWING EXIT EMERGENCY EXIT LIGHTS INOP AT ROW 24. REPL BATTERY PACK PER AMM 33-53. OPS CHECK GOOD. (LP5588474)SDR DALA2019091605321Fitting · crackedUPPER LT FITTING ON TAILCONE CRACKED. REMOVED UPPER LT TAILCONE FITTING. REPLACED UPPER LT FITTING ANGLE PER SRM 53-54-0 PAGE 3. OK FOR SERVICE. (LP1272698)SDR DALA2019091605320Bearing · excess playTAIL CONE RELEASE HAS PLAY AND IS CONTACTING THE FRAME. REMOVED TAIL CONE MECHANISM PER AMM 53-53-02. 542402. REPLACED RELEASE CAM BEARING IAW CMM 53-50-07. REINSTALLED MECHANISM IAW AMM53-53. NO PLAY NOTED PASSED TORQUE CHECK. (LP1272607)SDR DALA2019091605319Frame · crackedTAILCONE ATTACH FRAME CRACKED @2:00 POSITION AT PIN. REMOVED FRAME P/N 9911843-6. DRILLED UP REPLACEMENT FRAME P/N 5966769U501 PER DWG 9911843. (458779) INSTALLED NEW FRAME IAW DWG 9911843. (LP1272701)SDR DALA2019091505311Battery · dischargedFOUND OVERHEAD EMER LIGHTS OUT FROM ROW 22-25. REMOVED AND REPLACED EMER LT BATTERY PER AMM 33-52. OPS CHECK GOOD AC OK FOR SERVICE. (LP6125224)SDR DALA2019091305296Battery Pack · dischargedROW 25 OVERWING EMERGENCY EXIT SIGNS INOP. REPL BATTERY PACK PER AMM 33-53. OPS CHECK GOOD. (LP5597571)SDR DALA2019091305295Unknown · malfunctionedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. EMERGENCY FLOOR LIGHTING DAMAGED OR INOP. TRACK LIGHTING GOES ON & OFF. CHECKED OPERATION OF EMERGENCY LIGHTS - UNABLE TO DUPLICATE PROBLEM - SYSTEM OP'S NORMAL REF AMM 33-53. (LP1267573)SDR DALA2019091205279Battery · dischargedFWD FLIGHT DECK / GALLEY OVERHEAD EMERGENCY LIGHT INOP. REPLACED BATTERIES FWD DROP DOWN CEILING FOR FWD FLIGHT DECK GALLEY OVERHEAD EMRG LIGHT IAW AMM 33-50. OPS CHECK GOOD. (LP6188026)SDR DALA2019091005241Turbine · failedHYD QTY AT PUSH ON LEFT SYSTEM WAS 11 QTS DROPPED TO 7 QTS BY TIME WE REACHED THE RUNWAY. FA'S REPORTED A FAINT ODOR RTN TO GATE. NOTICED DROP IN PRESSURE AFTER ENGINE WAS STARTED AND RUNNING. FOUND APU TURBINE FAILING, LEAK OIL INTERNALLY. R/R APU PER AMM 49-SDR DALA2019090905205Battery · dischargedL & R AFT OVERTWING DOOR EMERGENCY LTS INOP. REMOVED AND REPLACED BATTERIES PER AMM 33-53 OPS CHECK NORMAL. (LP5485996)SDR DALA2019090805204Light · inoperativeEPLS SEAT LIGHT AT SEAT 16E INOP. REPLACED EPLS SEAT LIGHT OPS CHECK GOOD MD88 AMM 33-53. (LP5597622)SDR DALA2019090605201Light · missingROW 34ED AISLE PATH LIGHT MISSING. INSTALLED MISSING LIGHT IAW AMM 33-53 OPS CHECK GOOD. (LP6016707)SDR DALA2019090805202Frame · crackedRT FWD MAIN LANDING GEAR WHEEL FRAME CRACK. INSTALLED NEW RT FWD MLG W/W FRAME SECTION REF ERA 581127-14 REV 0 PERMANENT REPAIR. (LP6026692)SDR DALA2019090305107Battery · dischargedINTERIOR EMERGENCY EXIT OVERWING LIGHTS INOP. R/R BATTERIES IN BATTERY PACK PER AMM 33-53. NOW OPS NML. (LP6121960)SDR DALA2019090305106Battery Pack · dischargedCOCKPIT EMER LIGHTS STA 140 NOT ILLUMINATE WHEN DOING EMER LIGHT CHECK. REPLACED B5-23 BATTERY PACK PER AMM 33-50-00 FIG 1. SYSTEMS CHECK NORMAL. (LP4634454)SDR DALA2019090205111Wire · pulledFA REPORTS DURING TAKEOFF EMERGENCY LIGHTS WERE FLASHING. COCKPIT SW. IN ARM FA SW. OFF. FA LATER REPORTED EMERGENCY LIGHTS ON BUT VERY DIM. FOUND WIRES PULLED OUT OF CONNECTOR AT SEAT 26E. REPLACED SEAT EMERGENCY LIGHT EXTENSION HARNESS. ALL CKS GOOD PER WDM SDR DALA2019090105109Fuse · blownSEAT 31DEF THROUGH 36DEF SEAT MOUNTED EMERGENCY LIGHTS INOP. REPLACED FUSE 1 IN BATTERY PACK B5-212 REF AMM 33-53 CHECKS GOOD. (LP6018365)SDR DALA2019090205110Computer · malfunctionedSTALL INDICATION FAILURE MESSAGE ON EOAP ON GROUND. WOULD NOT CLEAR. MULTIPLE LOTS STALL WARN 2 CORD ON RESET BUT COMP HAS ELECT SMELL & TEST SW STICKS INTO IN NORMAL. R&R SAME. OPS NORMAL. REF AIM 34_19. COMPUTER, STALL OFF 88-3415-9-0001 S/N01946. (LP4623602SDR DALA2019083105108Socket · burnedFWD LAV FLUORESCENT LIGHT BURNED OUT ODOR OF BURNED INSULATION OR BALLAST. C/W NO GO ODI CHECKLIST 2172 C/W JIC 2120-2367 FOUND F/C LAV AFT LIGHT UPPER SOCKET ASSEMBLY WITH HEAT DAMAGE R/R SOCKET ASSY IAW WSPM 20-31 NO SMOKE/ODOR PRESENT CHKS GOOD OK FOR SVC. SDR DALA2019090305105Frame · crackedDURING SVC CK FOUND RT FWD MAIN LANDING GEAR FRAME CRACK. REMOVED AND REPLACED RT MLG FWD O/B FRAME SECTION REF. ERA581024-14 REV. ORIGINAL - SECTION - II PERMANENT REPAIR. REPAIRED INTERCOSTAL 5930584-31 REF. SRM 53-01 FIG.2 SH.3. PENDING DOOR OPS CHECK. (594SDR DALA2019090105104B-Nut · looseON POST FLIGHT FOUND MORE RESIDUAL FLUID ENTERING APU FWD NON RAM DOOR INLET. AFTER ENGS SHUT DOWN AND APU SUPPLY TO PACKS NOTICED BURNING OIL ODOR IN COCKPIT COMPLETED A/C SMOKE FUME QUESTIONNAIRE. INSPECTED FOR LEAKS AROUND TAIL COMP, SPUN ENGINES, RAN THRUSSDR DALA2019083005078Slide · low pressureFOUND L1 DOOR SLIDE PRESSURE LOW. R & R THE L1 DOOR SLIDE IAW WORKCARD 2561-4964. OK FOR SVC. SLIDE, PASSENGE OFF 09-2561-9-0011.SDR DALA2019083005077Fuse · failedDURING SVC CK FOUND FIRST 7 ROWS OF EEPLS LIGHTING INOP. REPLACED BLOWN FUSE ON EMERGENCY POWER SUPPLY B5-211 OPS CK GOOD PER MD88 AMM 33-53. OK FOR SVC. (LP5966718)SDR DALA2019082905055Battery · dischargedGALLEY / COCKPIT EMERGENCY LIGHT FOUND TO BE INOP DURING SVC CHECK. REPLACED D CELL NICD BATTERIES FWD DROP DOWN CEILING IAW AMM 33-50.OPS CHECK GOOD.SDR DALA2019082905057Smoke Detector · malfunctionedF/C LAVATORY SMOKE DETECTOR WILL NOT TURN OFF. SMOKE DETECTOR BEEPING. R AND R F/C LAV SMOKE DET REF MD88 M/M 26-17. CKS GOOD. (LP1244638)SDR DALA2019082905056Engine · failedATB - DUE TO RIGHT ENGINE ISSUES. FLT CREW REPORTED DURING CLIMB RIGHT OIL PRESSURE WENT TO 57 PSI AND FELT VIBRATION. FLIGHT ATTENDANT REPORTED LIGHT SMOKE IN CABIN. PER QRH REDUCED THROTTLE FOR REMAINDER OF FLIGHT. MTC FOUND METAL ON MCD ANALYZED AS M50 ANDSDR DALA2019082805009Cable · frayedFOUND KEVLAR CABLE IN TAIL CONE FRAYED WHILE WORKING 88-0553-8-0066. REPLACED TAILCONE KEVLAR CABLE REF MD88 AMM 53-53 AND DRAWING LONG BEACH 5913350.SDR DALA2019082704978Battery Pack · inoperativeEMERGENCY LIGHTS IN CEILING IN CABIN SECTIONS ARE INOP. RELAMPED SEVERAL LIGHTS THAT HAD INCORRECT BULBS. RPLD BATTERY PACK AT ROW 12 PER MD88 AMM 33-53. LIGHTS NOW CK GOOD. (LP5375862)
Back to Mcdonnell Douglas MD-88