What was found
UPON ACTIVATION OF NOSE LANDING LIGHT, ON FINAL APPROACH, GOT SPARK BECAUSE OF ELECTRICAL SHORT. FOUND 2 WIRE TERMINALS CONTACTING EACH OTHER ON NOSE LANDING LIGHT SWITCH. REPOSITIONED TERMINALS PER SWPM 20-20. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON ACTIVATION OF NOSE LANDING LIGHT, ON FINAL APPROACH, GOT SPARK BECAUSE OF ELECTRICAL SHORT. FOUND 2 WIRE TERMINALS CONTACTING EACH OTHER ON NOSE LANDING LIGHT SWITCH. REPOSITIONED TERMINALS PER SWPM 20-20. OPS CHECK GOOD.