SDR DALA20190603359Battery Pack · inoperativeAFT EXIT ROW EMERGENCY LIGHTS INOP (ROW 25). REPLACED BATTERY PACK ABOVE SEAT 25D. OPS CHECK GOOD REF MD88 AMM 33-53. (LP5428621)SDR DALA201906032358Smoke Detector · malfunctionedAIRCRAFT LEFT AFT LAV SMOKE DETECTOR IS CHIRPING. REMOVED & REPLACED AFT LEFT LAV SMOKE DETECTOR. OPS CHK GOOD. (LP1102304)SDR DALA2019060323357Generator · disconnectedAT 12,000 MSL, AUTO THROTTLES/AUTOPILOT DISCONNECTED L AC BUSS OFF, AND AC CROSS TIE LOCKOUT, L GEN OFF STALL IND FAIL, ON OAP, RAN QRH FOR LAC BUS OFF & AC CROSSTIE LOCKOUT. STARTED TO DESCEND AND CONFIGURE FOR LANDING AT FLAPS 15 GEAR DOWN, WE NOTICED THERE SDR DALA20190603361Housing · leakingSTRONG SMELL OF GASOLINE IN COCKPIT AND CABIN WHEN APU STARTED AFTER LANDING. C/W REQUIREMENTS OF NO GO ODI PREVENTION 2172. FOUND LEAKING FUEL FILTER HOUSING. REPLACED PACKING ON FILTER HOUSING PER B717 AMM 49-30. LK CHECK GOOD. PERFORM FULL DUCT BURNOUT PER SDR DALA2019053103332Wire · burnedUPON ARRIVAL TO RAMP IN ATL AND APU SPOOL UP SMELLED ELEC BURNING, A/C CROSSTIE LOCKOUT, RIGHT GEN FELL OFF LINE, APU GEN PICKED UP LOAD, SPARK WAS SEEN IN FIRST CLASS SEAT 1 C/D OVERHEAD. RAN SMOKE/FIRE/FUME CHECKLIST. CABIN STAND BY LGTS C/B, (L) COND REG VASDR DALA2019053103331Nose Cowl · dentedON WAKEUP CK FOUND #2 ENG LARGE DENT APPOX 3" LONG AND .250" DEEP IN NOSE COWLING AT 4 O'CLOCK POS. REMOVED #2 ENG NOSE COWL PER AMM 71-10-01 INSTALLED #2 ENG NOSE COWL PER AMM 71-10-01. COWL, NOSE, LT OFF 88-7110-9-0001 02236 ON 88-7110-9-0001 49422. (LP62537SDR DALA2019053003317Unknown · smokeSMOKE AND ODOR FROM BOTH AFT LAV'S AREA. FOLLOWED TROUBLESHOOTING ON WORKCARD 2120-2367. VISUALLY INSPECTED BOTH PACK FANS AND RECIRC FA. ALL OPS NORMAL. VISUAL INSP BOTH AFT LAVS AND OVHD AREA. NO ISSUES. CKD HOT AIR DUCTS ON BOTH PACKS. NO CONTAMINATION. APUSDR DALA2019053003316Wire · damagedREF WDM 35-24-01 WIRE W638CL20 HAS HEAT DAMAGE IN F/C CABIN OVER HEAD AREA. REMOVED AND REPLACED WIRE #W638CL20 FROM CONNECTOR R5-1200 PIN FF TO BUTT SPICE REPAIR ABOVE CEILING PANEL ROW 2CD PER SPWD 20-31. WIRING CKS IAW WDM 35-24-01. PERFORMED PAX O2 SYSTEM SDR DALA2019053003315Wire · burnedREF WDM 30-31-03 PG 2 WIRE F1551B20 FOUND BURNT THROUGH IN OVERHEAD F/C CABIN. RAN AND SPLICED WIRE F1551B20 IAW SWPM 20-10. TERMINATED AT R5-1201 IAW SWPM 20-31. 903393. WIRING CKS C/W IAW WDM 30-31-03. 399270. OPS CHECK PRIM STAM TRIM MOTOR HEATER PER AMM 27SDR DALA2019052903281Terminal · out of positionFA REPORTS THAT EMERGENCY LIGHTS FLICKERS ON/OFF AT HALF BRIGHTNESS AT 3-4 MINUTE INTERVALS IN FLIGHT. FOUND OVERHEAD EMERGENCY LIGHT SWITCH TERMINAL TOUCH ADJACENT STRUCTURE. REPOSITION TERMINAL. PER WDM 33-51. REF SWPM CH 20. CKS GOOD. (LP5564892)SDR DALA2019052903280Control Cable · brokenAIRPLANE ROLLED LEFT WITH SPOILER DEPLOYMENT WITH AUTOPILOT ON OR OFF ALL SPEEDS. ALSO FELT IT WHEN ACTUATING AILERONS WHILE FLYING MANUALLY (SOME LEFT ROLL PRESSURE WHEN AILERONS NEUTRAL). GND SPOILER F/D CHECK IS OK. DID FLIGHT AND GROUND SPOILER VISUAL CHECSDR DALA2019052803195Door · dentedL1 ENTRY DOOR FWD LOWER CORNER HAS LARGE DENT/CREASE IN SHEET METAL. REPLACED L1 DOOR. DOOR, ENTRANCE, OFF 92-5210-9-0001 00084 ON 92-5210-9-0001 00011. (LP5454093)SDR DALA2019052803188Doubler · damagedAWR: HIDDEN ELONGATED HOLES: DURING MTC WORKS IN REF NRC S/N 00194. ELONGATED HOLE ON EXTERNAL REPAIR DOUBLER AT VERTICAL STABILIZER FIXED L/E BELOW THE SPLICE AT STATION ZFS= 52.267 WERE FOUND. EXTERNAL REPAIR DOUBLER AT VERTICAL STABILIZER FIXED L/E WAS REPLSDR DALA2019052803196Smoke Detector · defectiveLEFT AFT LAVATORY SMOKE DETECTOR SOUNDING CONSTANTLY/NO SMOKE OR ODORS PRESENT. THE SMOKE DETECTOR WAS REPLACED. (LP1089857)SDR DALA2019052803189Doubler · crackedAWR: HIDDEN CRACK: DURING MTC WORKS IN REF NRC S/N 00194, CRACK ON INTERNAL FINGERS DOUBLER AT VERTICAL STABILIZER FIXED L/E BELOW THE SPLICE STATION ZFS= 52.267. INTERNAL FINGERS DOUBLER AT VERTICAL STABILIZER FIXED L/E WAS REPLACED PER SRM 51-30-01, 51-30-05SDR DALA20190603360Fire Warning · false activationNO 1 ENGINE FREE LOOP B CAME ON AT CRUISE. CHECKLIST COMPLETED FREE LOOP A TEST GOOD. T/S PER MD88 AMM 26-10. INSPECTED, CLEANED, AND SECURED FIRE LOOPS. FOUND INSULATION ON ONE CLAMP INBOARD SIDE OF ENGINE DISPLACED AND NOT SECURED PROPERLY. UNABLE TO DUPLICASDR DALA2019052903313Apu · malfunctionedAPU FAILED DURING RIGHT ENG START. SMOKE APPEARED IN THE AFT CABIN AND SOON DISIPATED. INSTALLED APU REF CARDS 4900-2121, 4900-4573, 4900-7165, 4900-4169,. C/W NO GO ODI PREVENTION ATA 4999, ATA 2172 PER CARDS 4900-1185, 2121,2368, 7100-2619. APU OPN NORMAL. (SDR DALA2019052403178Sign · missingOVERWING EMERGENCY EXIT SIGNS MISSING. MAINTENANCE REPLACED THE EXIT SIGNS COVER. AIRCRAFT IS OK FOR SERVICE. (LP #4788928)SDR DALA2019052403177Floor Panel · unserviceableAFT CARGO FLOOR PANELS IN POOR CONDITION. UPON INSPECTION FOUND FLOOR PANEL 181HF TO BE IN SERVICABLE CONDITION. REMOVED, FABRICATED, AND INSTALLED PANELS 181FF AND 181DF PER AMM 25-52. (LP #4696698)SDR DALA2019052103112Access Panel · missingFOUND ON ARRIVAL #1 ENG UPPER COWLING MISSING ACCESS PANEL. I/B SIDE JUST AFT OF NOSE COWL. INSTALLED #1 ENG INBD PANEL. (LP5564856)SDR FXGA201905201944Skin · not reportedFUSELAGE SKIN REPAIR AT F/STA 235 LONGERON 19L. SRM 53-04-3 FIGURE 11. PERFORM REPAIR PER SRM 53-04-3 FIGURE 11. THIS IS A CLASS 1 REPAIR AND REQUIRES RE-INSPECTION.SDR DALA2019052003080Hook And Loop · wornTAILCONE SLIDE COVER HOOK AND LOOP IS WORN. REPLACED THE TAILCONE SLIDE ASSY. REF AMM 25-62-01. SLIDE OFF 88-2561-9-0003 01758 ON 88-2561-9-0006 01734 LOG-PAGE UPDATED @ 20MAY19 0300 UTC. (LP1082377)SDR DALA2019052003079Frame · crackedCRACK WITH LOOSE MISSING FASTENERS AT CANTED FRAME 1485, LEFT SIDE, AFT OF UPPER VENT. REPAIRED IN REF TO SRM 53-03D, PARA 44, FIG.50. (LP1081922)SDR DALA2019051903078Light · inoperativeEMER. LIGHT @ PAX 14D INOP. RELAMPED SAME CKS GOOD. (LP5722120)SDR DALA2019051703077Skin · damagedDAMAGE AT STA 484 3" BELOW STR 24R. REF N/R 5. INSTALLED REPAIR DOUBLER REF. SRM 53-04-3.REF N/R 5. LOG ENTRY FOR LFEC REINSPECT. PLEASE SET UP. (LP1077538)SDR DALA2019051703076Skin · damagedDAMAGE AT STA 484 3" BELOW STR 24R. INSTALLED REPAIR DOUBLER REF. SRM 53-04-3. DAMAGED AREA PAINTED ON N/R 9. (LP1077364)SDR DALA2019051703075Skin · damagedDAMAGE AT STA 541 AT STR 25R. INSTALLED REPAIR DOUBLER REF. SRM 53-04-3. DAMAGED AREA PAINTED ON N/R 9. (LP1077363)SDR DALA2019051703074Stringer · corrodedAFT CARGO COMPARTMENT BILGE AREA:CORROSION AT STRINGER STA.1287, LONGERON 29LT. MKD. REPAIRED REF SRM 53-02 PARA 12 FIG 18. (LP1077190)SDR DALA2019051703070Doubler · damagedDAMAGE AT STA 541 AT STR 25R REF N/R 4. INSTALLED REPAIR DOUBLER REF SRM 53-04-3 FIG 8 SHEET 3. REF N/R 4. (LP1077522)SDR DALA2019051603066Light · inoperativeEMERGENCY ESCAPE PATH LIGHT INOP @19D. REPL LIGHT ASSY PER AMM 33-53. OPS CHECK GOOD. (LP5822389)SDR DALA2019051603065Light · inoperativeEMERGENCY ESCAPE PATH LIGHT INOP AT 11D. REPL LIGHT ASSY PER AMM 33-53. OPS CHECK GOOD. (LP5504375)SDR DALA2019051603073Switch · defectiveCABIN ROWS 20 / 21 SEATS CDE MASKS DID NOT DEPLOY. REPLACED ROW 20 DE + ROW 21 DE LATCHING SWITCH PER AMM 35-20-00. DROP CHECK NEED TO BE DONE. PERFORMED DROP CHECK PER AMM CH 35-21-01 OPS CHECK GOOD. (LP5844493)SDR DALA2019051603072Outflow Valve · obstructedSHIP 907 - PRESSURIZATION - DECLARED EMERGENCY INTO MIA DUE TO LOSS OF AUTO PRESSURIZATION. MASKS DEPLOYED. CORRECTIVE ACTION: MTC. FERRY TO ATL - ATL MAINTENANCE FOUND SCREW BLOCKING FULL ROTATION OF OUTFLOW VALVE WHEEL IN CENTER PEDESTAL. THE SCREW WAS REMOVSDR DALA2019051603068Doubler · wornAWR WORN ON PREVIOUS REPAIR DOUBLER STA XFLS 158 LEADING EDGE AT RT WING ON REFERENCE MON /097/023 LOG 2981072. DOUBLER WAS REPLACED PER ER/A 557670-14 REV. ORIGINAL SECTION I. (LP1075873)SDR DALA2019051603067Vane · damagedINITIAL INSPECTION; MISSING COMPOSITE MATERIAL AND PUNCTURE ON LOWER SKIN SURFACE ON MID FLAP GUIDE VANE AT OUTBD FLAP RT WING. OUTBD FLAP RT WING WAS REMOVED PER AMM 27-51-03-201 STEP 3 AND GUIDE VANE AT OUTBD FLAP PN: 5910042-512 S/N: DL120 RT WING WAS INSTASDR DALA2019051503018Light · inoperativeSEAT 3CD E/E LIGHTS INOP. RELAMPED SAME PER AMM 33-53. CKS GOOD. (LP5818198)SDR DALA2019051503019Radome · damagedFOUND SMALL DAMAGED AREA TO THE RADOME. R/R NOSE RADOME PER AMM 53-50. OPS CKS GOOD RADOME, NOSE, D OFF 88-5351-9-0002 00077 ON 88-5351-9-0002 01938. (LP5471157)SDR DALA2019051503017Cowling · dentedNR 1 ENG. NOSE COWL LIP HAS DENT AT APPROX. 2 O'CLOCK POSITION. REPLACED NR 1 ENGINE NOSE COWL, REF AMM 71-10-01. COWL, NOSE, LT OFF 88-7110-9-0001 99491 ON 88-7110-9-0001 00084. (LP1074461)SDR DALA2019051403011Light · inoperativeEMERGENCY LIGHT OVER DOOR AT 24A INOP. RELAMPED SAME OPS NML REF AMM 33-52. (LP4751576)SDR DALA2019051302969Unknown · odorAFTER NR 2 ENGINE START, AFT RT LAV SMOKE DETECTOR WENT OFF. FLT ATT STATED THERE WAS A SWEET PEPPERY SMOKE SMELL. C/W NO GO OPDIO PREVENTION PROGRAM ATA 2172. C/W JIC 7100-2619. NO SMOKE NO ODORS. A/C OK FOR SVC. (LP5613270)SDR DALA2019051002927Megaphone · damagedREF CARD 2500-4425: DURING OPERATIONAL CHECK OF MEGAPHONE HARDWARE DAMAGED WAS FOUND. MEGAPHONE P/N: A3-06-1402-1 S/N: 3522 WAS REMOVED AND SERVICEABLE MEGAPHONE P/N: EM1D S/N: N/A WAS INSTALLED AND INSTALLATION TEST WAS PERFORMED PER AMM 23-34-00. INSTALLATIOSDR DALA2019050902914Light · inoperative15 D SEAT EMERGENCY LIGHT INOP. R&R LIGHT ASSY AT SEAT 15D OPS NML REF AMM 33-52. (LP5654544)SDR DALA2019050902913Light · inoperativeSEAT 29DE EMERGENCY LIGHT INOP. RELAMPED EMERGENCY PATH LIGHT AT 29DE & OPS CK GOOD. (LP5653546)SDR DALA2019050902912Light · damagedEMERGENCY LIGHT ASSY DAMAGED AT 32D. REPLACED LIGHT ASSY AT 32D OPS NL REF AMM 33-52. (LP5800382)SDR DALA2019050802895Battery · dischargedCABIN STANDBY LIGHTS BETWEEN STA.1100 AND STA. 1200 INOP WHEN TESTED. REPLACED BATTERIES IN POWER PACK IAW AMM 33-52. CHECKS GOOD. (LP5654060)SDR DALA2019050802894Connector · not seatedEMERGENCY LIGHT INOP ABOVE CATWALK IN AFT ACCESSORY COMPARTMENT. RESEATED CONNECTOR FOR LIGHT ASSY LIGHT CKS OK. (LP5721405)SDR DALA2019050802893Connector · disconnectedFOUND 25DE EXIT ROW LIGHT INOP. VISUALLY INSPECTED LOOSE CONNECTOR UNDER SEAT 25D. RECONNECTED, CK GOOD, REF AMM 25-53. (LP5822293)SDR DALA2019050802892Battery Pack · dischargedDURING CK FOUND FIRST CLASS CEILING PANEL EMERGENCY LIGHTS INOP. REMOVED AND REPLACED BATTERY PACK IN PWR SUPPLY B5-100 IAW AMM 33-53. OPS CKS NML. (LP5800797)SDR DALA2019050702858Generator · malfunctionedSHIP 0957 - ATB - AT ROTATION LOST THE LEFT ENGINE GENERATOR AND HAD A CROSS TIE LOCKOUT. CREW DECLARED EMERGENCY AND RETURNED TO ATL. CORRECTIVE ACTION: PERFORMED TROUBLESHOOTING AND ISOLATED TO CROSS TIE RELAY. REPLACED CROSS TIE RELAY AND THE RIGHT SYMBOL GSDR DALA2019050602813Lanyard · defectiveSLIDE FAILED TO DEPLOY WORK CARD # 88-0525-8-0408 SLIDE D29984-213 S/N 1241 MFG DATE MAR 2000. FND LANYARD ON COVER BAD REPLCD SAME. (LP1060688)
Back to Mcdonnell Douglas MD-88