Sikorsky S-76A
Service difficulty reports · 2,806
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'S76A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'S76A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HEEA0016227Actuator · chattersACTUATOR CHATTERS.SDR HEEA0016226Actuator · malfunctionedACTUATOR TRAVELS TO THE RIGHT AND BACK TO CENTER, BUT WILL NOT TRAVEL TO THE LEFT.SDR HEEA0016225Actuator · chattersAFCS ACTUATOR CHATTERING.SDR HEEA0016224Actuator · chattersACTUATOR CHATTERING.SDR HEEA0016223Actuator · chattersACTUATOR CHATTERING.SDR HEEA0016222Actuator · chattersACTUATOR CHATTERS, JERKS.SDR HEEA0016221Actuator · chattersACTUATOR CHATTERS IN-FLIGHT.SDR HEEA0016220Actuator · chattersACTUATOR CHATTERS WHEN ENGAGED.SDR HEEA0016219Actuator · kicksACTUATOR KICKS IN-FLIGHT.SDR HEEA0016218Actuator · kicksACTUATOR KICKS IN-FLIGHT.SDR HEEA0016217Potentiometer · failedNR 2 YAW AFCS CHANNEL INOPERATIVE. POTS WERE SCRAPPED.SDR HEEA0016216Actuator · chattersACTUATOR CHATTERS AND SHAKES CYCLIC.SDR HEEA0016215Actuator · inoperativePILOT REPORTED ACTUATOR TO BE INOPERATIVE. INSPECTED BY ACCESSORY OVERHAUL SHOP AND FOUND POTENTIOMETERS HAD NO INDICATION.SDR HEEA0016214Actuator · malfunctionedROCKS IN-FLIGHT. INSPECTED BY ACCESSORY OVERHAUL SHOP AND FOUND NR 1 POTENTIOMETER IS INOPERATIVE.SDR 98ZZZX4752Governor · malfunctionedON 10-27-98 DURING DEPARTURE FROM LAFAYETTE BASE, EXPERIENCED NR 2 ENGINE HIGH SIDE FAILURE. RETURNED FOR MAINTENANCE. REPLACED NR 2 GOVERNOR.SDR 98ZZZX4756Wire · failedPILOT SMELLED BURNING WIRES IN THE COCKPIT, CONTINUED TO NORMAL LANDING. REPAIRED BURNT WIRES IN PILOT'S OVERHEAD COMPARTMENT.SDR AU981366Liner · corroded(AUS) TAIL ROTOR PITCH CHANGE SHAFT LINER CORRODED CAUSING BINDING OF THE PITCH CHANGE SHAFT.SDR AU981356Shaft · corroded(AUS) TAIL ROTOR PITCH CHANGE SHAFT BINDING ON LINER DUE TO CORROSION.SDR 98ZZZX4753Engine · failedIN-FLIGHT, NR 2 ENGINE OIL PRESSURE DROPPED WITH OIL PRESSURE LIGHT ILLUMINATION. PILOT SECURED ENGINE AND MADE UNEVENTFUL SINGLE ENGINE LANDING. MAINTENANCE FOUND 3 QUARTS OIL CONSUMPTION AFTER REPLENISHING OIL. SEVEN MINUTES INTO PENALTY RUN, OIL CONSUMPTSDR 98ZZZX4757Adi · malfunctionedDURING CLIMB-OUT, SMOKE WAS NOTICED IN THE COCKPIT. FOUND COPILOT'S ADI DEFECTIVE. REMOVED AND INSTALLED SERVICEABLE UNIT.SDR HEEA0016070Module · malfunctionedMODULE CYCLES CONTINUOUSLY WHEN ON. UNIT INSPECTED BY ACCESSORY OVERHAUL SHOP. REPLACED O-RINGS AND BEARINGS DUE TO CONTAMINATION.SDR HEEA0016069Rotor Brake · inoperativeROTOR BRAKE INOPERATIVE. REPLACED WITH SERVICEABLE UNIT.SDR HEEA0016068Rotor Brake · malfucntionedWITH ROTOR BRAKE ON AND ROTOR SPOOLING DOWN (STILL TURNING)...WINDSHIELD HOT BUS TIE OPEN TFMR RECT AND DOOR OPEN WARNING LIGHTS CYCLE ON AND OFF ON MASTER CAUTION PANEL UNTIL ROTOR COMES TO A COMPLETE STOP. ROTOR BRAKE FUNCTION NORMAL. UNIT CURRENTLY IN ACCSDR HEEA0016067Rotor Brake · malfunctionedROTOR BRAKE MOTOR RUNS CONTINUOUSLY AND NEVER BUILDS UP PRESSURE (SUSPECT VALVE STUCK CLOSED). UNIT INSPECTED BY ACCESSORY OVERHAUL SHOP. THERE WAS NO PROBLEM FOUND WITH UNIT.SDR HEEA0016066Relay · failedBAD FROM STOCK - MICROSWITCH STUCK 12 AND 13 DOES NOT OPEN WHEN RELAY IS PULLED. REMOVED AND REPLACED WITH SERVICEABLE RELAY.SDR HEEA0016065Relay · failedTRANSFORMER RECTIFIER NOT SUPPLYING POWER TO EMS EQUIP. CONTACTS B2 AND B3 SHOULD HAVE CONTINUITY WITH RELAY AT REST TO ALLOW EMS TRANSFORMER RECTIFIER TO SUPPLY POWER TO EMS SYSTEMS. THIS RELAY DOES NOT. REMOVED AND REPLACED WITH SERVICEABLE RELAY.SDR HEEA0016050Spur Gear · wornENGINE REMOVED DUE TO IMPELLER TIME. INSPECTION OF COMPRESSOR PARTS NOTED: STEP WEAR BEYOND SERVICEABLE LIMITS ON SHAFT SPLINES.SDR HEEA0016037Altimeter · failedNEEDLE STICKING AND HAS EXCESSIVE LEAKAGE WHEN BARO KNOB IS TURNED AT 18,000 FEET.SDR HEEA0016036Bearing · failedBEARING FAILURE, FOUND METAL SHAVING ON SEALS AND ROUGH ROTATION. REPLACED WITH SERVICEABLE BEARINGS.SDR HEEA0016032Blade · damagedPADDLE 'A' HAS A HOLE IN THE LEADING EDGE ABRASION STRIP.SDR CA980928005Fuel Control · faulty(CAN) ENGINE STARTED HOT AND DID NOT IMMEDIATELY SHUT DOWN WHEN THE THROTTLE WAS STOP COCKED. FUEL LEVER WAS STOP COCKED AND 3-5 SECONDS LATER, THE ENGINE SHUT DOWN. THE FUEL CONTROL UNIT WAS FOUND FAULTY.SDR AU981163Sensor · failed(AUS) NR 1 ENGINE OVERSPEED SENSOR FAULTY. PART TC: 900.SDR HEEA0015950Potentiometer · failedCAUSING ACTUATOR NOT TO OPERATE. FOUND POTS CHECKED BAD IN NULL POSITION.SDR HEEA0015949Potentiometer · failedPOTENTIOMETER CHECKS BAD IN NULL POSITION.SDR HEEA0015948Potentiometer · malfunctionedCAUSED ACTUATOR TO BE INOPERATIVE. INSPECTED BY ACCESSORY OVERHAUL SHOP AND FOUND POTS CAUSED ACTUATOR TO TEST OUT OF LIMITS ON TEST POINTS 9(Q) 3 & 5 (MECHANICAL CENTER OUT OF LIMITS AFTER SETTING ELECTRICAL CENTER) AND STRIP CHART INDICATED BADAREAS IN NULLSDR HEEA0015935Encoder · malfunctionedNEEDLE STICKS THROUGHOUT SCALE AND ENCODER READS OUT OF TOLERANCE.SDR HEEA0015932Caution Panel · failedSPARE SEGMENT ON CAUTION PANEL DOES NOT ILLUMINATE.SDR HEEA0015929Control Unit · failedGENERATOR WOULD NOT RESET.SDR HEEA0015928Indicator · failedRT FLAG ATTITUDE INDICATOR WILL NOT PULL.SDR HEEA0015904Indicator · failedDURING TAKEOFF, AIRSPEED INDICATES NEGATIVE AIRSPEED UNTIL 60 KNOTS. READS CORRECTLY AFTER TAKEOFF AND CRUISE FLIGHT.SDR HEEA0015902Receiver · failedADF WILL NOT TEST, RECEIVED SIGNAL AND NEEDLE WILL NOT POINT.SDR HEEA0015894Receiver · weakVOR RECEIVER HAS WEAK RECEIVE, CAN BE OFF BY UP TO 7 POINTER.SDR HEEA0015893Receiver · malfunctionedADF SLOW TO RESPOND, KA135 CABLE BROKEN.SDR HEEA0015892Control Unit · malfunctionedAC GENERATOR DROPS OFF LINE WHEN AIR CONDITIONER IS TURNED ON.SDR HEEA0015841Interphone · malfunctionedFM 1 CHANNEL REPORTED GARBLED WHILE TRANSMITTING. VOLUME CONTROL SCRATCHY WHILE ROTATING.SDR HEEA0015830Gyro Compass · damagedGYRO COMPASS HAS LOOSE HARDWARE IN ASSY.SDR HEEA0015829Indicator · contaminatedINDICATOR FLUCTUATES, MOISTURE INSIDE.SDR HEEA0015828Compensator · crackedCOMPENSATOR CRACKED.SDR HEEA0015818Shaft · mismanufacturedSHAFT RECEIVED WITH NO HOLES.SDR 98ZZZX3607Amplifier · inoperativeON APPROACH FOR LANDING, NR 1 ENGINE STARTED TO YAW. LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE NR 1 DCA AMPLIFIER INOPERATIVE AND THE NR 2 DCA AMPLIFIER ERRATIC. REPLACED BOTH. REF: S76 IPC, CHAPTER 76-11-00, FIGURE 1-14, AND FIGURE 1-16.
Back to Sikorsky S-76A