LAX95LA278

NTSB accident investigation · Fox Peregrine PJ-2 · Minden, NV · August 4, 1995

Accident · FatalLimited investigationFinal report
Date
August 4, 1995, 09:26 local (16:26 UTC)
Place
Minden, NV
Injuries
1 fatal
Damage
Destroyed
Phase of flight
Approach
Aircraft
N62PJFox Peregrine PJ-2
Weather
Visual (VMC) · Day
Status
Completed · report April 1, 1996
Report
Approved by Office Director
Case key
29172

From the NTSB’s public API. By law, NTSB reports can’t be used as evidence in lawsuits over the accident.

On this page

Probable cause

a failure of the wing flap control system due to inadequate design, which led to an asymmetrical flap deployment during a critical flight condition and in-flight loss of control. A related factor was the lack of a split-flaps warning system.

Sequence of events

NTSB’s coding before 2008: each occurrence and phase of flight, and the causes and factors under it. The codes are defined in NTSB’s coding manual.

Airframe/component/system failure/malfunctionGo-around (vfr)
Flt control syst,wing flap control cable/rod - shearedCause
Acft/equip,inadequate designProduction/design personnelCause
Loss of control - in flightGo-around (vfr)
Warning system(other) - not installedFactor
Flight control,flap - asymmetricalCause
Aircraft control - not possiblePilot in command
In flight collision with terrain/waterDescent - uncontrolled

Analysis

The aircraft was on a developmental flight test program. The pilot reported a split flap situation during the go-around. Witnesses observed the airplane turn onto a left crosswind, then begin a right roll to ground impact. A pin in the left flap drive was found sheared. The pin was examined and found to meet the manufacturer's material specifications. It was determined the pin had failed due to overload shear forces while torsional and axial loads were applied. The flaps are driven by a single electric motor which rotates two independent flexible drive shafts that actuate the right and left flap panels. The sheared pin broke the continuity of the left flap panel drive stopping the flap panel while the right flap panel would continue to extend or retract. There was no system or mechanism in the airplane that detected an asymmetrical flap condition. Tests of the flap system revealed the electrical motor in the flap system was capable of shearing the pin before a circuit breaker would interrupt electrical power to the motor.

Factual narrative

On August 4, 1995, at 0926 hours Pacific daylight time, a Fox Aircraft Corp., Peregrine PJ-2, N62PJ, collided with terrain after an in-flight loss of control during a go-around from runway 34 at the Douglas County Airport, Minden, Nevada. The airplane was being operated as a developmental test flight under 14 CFR Part 91 when the accident occurred. The airplane was destroyed. The commercial pilot was fatally injured. Visual meteorological conditions prevailed at the time.

The pilot reported a split flap situation by radio to his company during the go-around. Witnesses reported seeing the airplane turn left to the crosswind leg of the traffic pattern and then roll to the right. The airplane pitch attitude was observed decreasing and the airplane continued to roll until colliding with terrain.

Examination of the flap system revealed a pin sheared on the left-hand drive shaft. The flaps are driven by a single electric motor which rotates two independent flexible drive shafts that actuate the right and left flap panels. Examination of system drawings and descriptions revealed that a sheared pin would break the continuity of the respective flap panel drive, stopping the flap panel while the other flap panel would continue to extend or retract. There was no system or mechanism in the airplane that detected an asymmetrical flap condition.

The pin was submitted to metallurgical lab for analysis. According to the metallurgist, the pin conformed to the material specifications of the pin manufacturer and had failed due to overload shear forces on an approximate 45-degree plane. The metallurgist indicated the orientation of the direction of shear would indicate that a combination of torsional and axial loads were being applied at the time of the shear failure.

The airplane manufacturer conducted tests of the flap system. The manufacturer determined the electrical motor in the flap system was capable of shearing the pin before a circuit breaker would interrupt electrical power to the flap motor.

Aircraft

Registration
N62PJ
Reported as
Fox Peregrine PJ-2 (PEREGRINE)
Category
Airplane
Serial number
001
Airframe hours
34
Engine
GE J85-17A, 2,950 lbs thrust, turbo jet
Damage
Destroyed
Flight
Part 91
Registered owner
Fox Aircraft Corp.
Airworthiness certificate
Special, Experimental (Special)
Last inspection
Continuous airworthiness · July 30, 1995 · 24 hours before
Departed
MEV
Airport
MEV · Douglas County, runway 34, 7,395 × 100 ft, asphalt

Matched to the registry by N-number and the event date; the registry’s history has gaps, so older matches can be wrong. Compare the reported make and model.

Flight crew

As NTSB recorded them. NTSB leaves out names.

Role
Pilot
Age
53
Certificates
Military, Commercial
Airplane ratings
Single-engine land, Multi-engine land
Instrument ratings
Airplane
Medical
Class 2, Valid Medical--w/ waivers/lim
Seat
Front
Toxicology
Performed
Flight hours
5,922 total · 14 in this make and model · 5,922 as pilot in command · 43 in the last 90 days · 18 in the last 30 days · 3 in the last 24 hours

Weather

Conditions
Visual (VMC) · Day
Wind
180° at 5 knots
Visibility
40 statute miles
Lowest ceiling
None
Temperature
75 °F, dew point 45 °F
Altimeter
30.00 inHg
Observed at
RNO, 28 nm away