Summary
This document proposes the supersedure of an existing airworthiness directive (AD), applicable to certain Airbus Model A300, A310, and A300-600 series airplanes, that currently requires a one-time operational test of the fire shut-off valves (FSOV) to determine if the FSOV's are functioning correctly, and replacement of failed parts with new or serviceable parts. This action would require repetitive performance of the operational test. This action would also limit the applicability to airplanes installed with certain FSOV's. This proposal is prompted by issuance of mandatory continuing airworthiness information by a foreign civil airworthiness authority. The actions specified by the proposed AD are intended to detect and correct failure of the FSOV's to close, which could result in failure of the engine fire shut-off system, and consequent inability to extinguish an engine fire.