Summary
We propose to adopt a new airworthiness directive (AD) for the products listed above. This proposed AD results from mandatory continuing airworthiness information (MCAI) originated by an aviation authority of another country to identify and correct an unsafe condition on an aviation product. The MCAI describes the unsafe condition as:
Several incidents have been reported where an electrical burning smell was noted in the cockpit, originating from the Electrical Power Centre. Troubleshooting revealed a partly molten terminal, which normally attaches a wire or bus bar to a stud of an Electrical Power Contactor, Part Number (P/N) SG02206. Furthermore, heat damage to the contactor stud itself was found. * * * * * * * *
This condition, if not corrected, could lead to further cases of overheating of terminals and studs of Electrical Power Contactors P/ N SG02206, possibly resulting in the loss of electrical power systems, electrical arcing and fire/smoke in the cockpit.The proposed AD would require actions that are intended to address the unsafe condition described in the MCAI.