NPRM FAA-2015-0822

Became AD 2015-17-15

Proposed airworthiness directive · Bombardier

Published
April 13, 2015 · 80 FR 19574
Comments due
May 28, 2015
Action
Notice of proposed rulemaking (NPRM)
Docket
FAA-2015-0822
Project
2014-NM-210-AD
FR document
2015-08329
Products
Aircraft

A proposal is not in force. If adopted, it becomes an AD, usually with changes. Only the Federal Register edition is official.

Summary

We propose to adopt a new airworthiness directive (AD) for certain Bombardier, Inc. Model CL-600-2C10 (Regional Jet Series 700, 701, & 702) airplanes, Model CL-600-2D15 (Regional Jet Series 705) airplanes, Model CL-600-2D24 (Regional Jet Series 900) airplanes, and Model CL-600-2E25 (Regional Jet Series 1000) airplanes. This proposed AD was prompted by results of a design review indicating that the burst pressure of the flexible hose, used to vent oxygen from the high- pressure relief valve of the oxygen cylinder overboard, was lower than the opening pressure of the high-pressure relief valve, which could cause the flexible hose to burst before it can vent the excess oxygen overboard. This proposed AD would require replacing the oxygen hose assembly with a new, improved assembly. We are proposing this AD to prevent the accumulation of oxygen in an enclosed space, which could result in an uncontrolled oxygen-fed fire if an ignition source is nearby.