What was found
ON APPROACH TO MSP, THE 'A' SYSTEM HYDRAULIC QUANTITY AND PRESSURE WENT TO ZERO. FLIGHT LANDED WITHOUT INCIDENT. MSP MAINTENANCE REPLACED BLOWN O-RING ON ELEVATOR/RUDDER FILTER RETURN MODULE. LEAK AND OPERATIONAL CHECK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON APPROACH TO MSP, THE 'A' SYSTEM HYDRAULIC QUANTITY AND PRESSURE WENT TO ZERO. FLIGHT LANDED WITHOUT INCIDENT. MSP MAINTENANCE REPLACED BLOWN O-RING ON ELEVATOR/RUDDER FILTER RETURN MODULE. LEAK AND OPERATIONAL CHECK OK.