What was found
DURING OVERNIGHT MAINTENANCE LINE CHECK, FOUND ZONE A EMERGENCY LIGHTS ILLUMINATE UNCOMMANDED WHEN FLIGHT DECK SWITCH IS ARMED. MAINTENANCE REPAIRED BROKEN EMERGENCY LIGHTS WIRES AT DOOR 1L PER AMM 33-51-00. OPERATIONAL CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING OVERNIGHT MAINTENANCE LINE CHECK, FOUND ZONE A EMERGENCY LIGHTS ILLUMINATE UNCOMMANDED WHEN FLIGHT DECK SWITCH IS ARMED. MAINTENANCE REPAIRED BROKEN EMERGENCY LIGHTS WIRES AT DOOR 1L PER AMM 33-51-00. OPERATIONAL CHECK GOOD.