As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND FLOORBEAM AT FRAME 36 CRACKED AT THREE LOCATIONS: A) 3 INCHES LENGTH AT Y+700. B) 3 INCHES LENGTH AT Y+900. C) 1 INCH LENGTH AT Y-700. *S/D* REMOVED AND REPLACED PER FEDEX EA 6-5100-52040 & A310 SRM SUPPLEMENTAL MANUAL 53-10-15, FIG 201. THE DEFECTS RECORDED ON THIS SNRM HAVE BE TRANSFERRED TO NR 407, NR 408, NR 409 AS EACH DEFECT HAS TO BE INDIVIDUALLY RECORDED ON A SEPARATE SNRM.