SDR 0100759853

Service difficulty report · Control Valve · Doug DC951

Difficulty date
February 22, 2001
Submitted
March 2, 2001
Operation
Air carrier
Aircraft
N762NC
Make and model
Doug DC951
Aircraft serial
47710
Aircraft time
61,182 hours, 63,987 cycles
Part
Control Valve
Part serial
00914
Condition
Contaminated
Location
Rt A/C Pack
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT ATTENDANT NOTIFIED CREW OF THE RIGHT AFT LAV SMOKE DETECTOR IN ALARM ALONG WITH A SMELL OF SMOKE IN THE AFT CABIN. AN EMERGENCY WAS DECLARED AND A SAFE LANDING WAS MADE IN JAX. NO EVIDENCE OF FIRE OR SMOKE WAS FOUND AFTER LANDING. SOME OIL RESIDUE WAS FOUND IN THE RIGHT WATER SEPARATOR TEMPERATURE CONTROL VALVE. REPLACED THE RIGHT WATER SEPARATOR TEMPERATURE CONTROL VALVE. REPLACED THE RIGHT WATER SEPARATOR BAG PRECAUTIONARY. AIRCRAFT RETURNED TO SERVICE.

More about the Doug DC-9-51