As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING MCK IN ATL CORROSION FOUND AND A DOUBLE DRILLED HOLE WERE FOUND IN THE LOWER SECTION OF THE JAMB OF THE AFT VENTRAL DOOR. THE CORROSION WAS REMOVED BY CUTTING OUT THE JAMB. AFTER REMOVAL OF THE REPAIR, CORROSION WAS ALSO FOUND IN THE JAMB. REPAIRED PER EA 98-185086.