What was found
During Mck in ATL, The aft portion of the lower cap of the pylon closing rib was found cracked. The crack is approximately .7" long and extends from a hole 3.7" from the end of the cap. Material TI-6AI-4V. Repaired per EA. 99-181307.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
During Mck in ATL, The aft portion of the lower cap of the pylon closing rib was found cracked. The crack is approximately .7" long and extends from a hole 3.7" from the end of the cap. Material TI-6AI-4V. Repaired per EA. 99-181307.