What was found
ON SHORT FINAL TO LAND HYDRAULIC LIGHT ILLUMINATED WHEN LANDING GEAR WAS SELECTED DOWN. PERFORMED HYDR LIGHT ON ABNORMAL CHECK LIST. 3 GREEN LANDING GEAR WAS ACHIEVED. UNABLE TO GAIN ANY FLAPS. PULLED EMERGENCY HANDLE TO GET GEAR 3 GREEN AND HAND PUMP WOULD NOT WORK. DURING TROUBLESHOOTING FOUND ELECTRIC DRIVEN HYDRAULIC PUMP TO BE INOPERATIVE. REMOVED AND REPLACED HYDRAULIC PUMP MOTOR IAW 29-10-075 PN ON/OFF 40185-02, SN ON EQ02, SN OFF AH-93471. ALSO PERFORMED LANDING GEAR SYSTEM RETRACTION AND EXTENSION IAW 32-30-00-5 OPS CHECK GOOD. FLAPS ALSO OPS CHECKED GOOD.