What was found
DURING CLIMBOUT, NR 2 IDG TEMP CONT TO CLIMB. VERIFIED NR 2 IDG DEFERRED CORRECTLY. VERIFIED PROPER SERVICE ACCOMPLISH. NO FAULTS NOTED. IDG TEMP WITHIN LIMITS REF MM 24-11-00-001. AC OK FOR SERVICE. NR 2 IDG REMAINS DEFERRED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CLIMBOUT, NR 2 IDG TEMP CONT TO CLIMB. VERIFIED NR 2 IDG DEFERRED CORRECTLY. VERIFIED PROPER SERVICE ACCOMPLISH. NO FAULTS NOTED. IDG TEMP WITHIN LIMITS REF MM 24-11-00-001. AC OK FOR SERVICE. NR 2 IDG REMAINS DEFERRED.