What was found
DURING ROUTINE INSP, FWD LWR CARGO COMP, DOOR CUTOUT, FRAME CRACKED AT BS 580 AT RBL 60 NEAR FWD STOP FITTING. *S/D* REMOVED PAIN, TREATED AND PRIMED AREA PER IAW BAC 727 SRM 51-10-2. HFEC IND NO CRACKS FOUND IAW B727 NDT MANUAL PART 6.