What was found
NR 3 ENGINE STRUT OVERHEAT LIGHT ILLUM. DURING CLIMBOUT 17000 FT NR 1 BLD OPEN, NR 2 BLD CLOSED. LIGHT EXTINGUISHED WHILE RUNNING CKLIST FOR STRUT OVERHEAT LIGHT. *S/D* REPLACED DUCT ASSY PER MM 36-00-001-2. OPS AND LEAK CK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 ENGINE STRUT OVERHEAT LIGHT ILLUM. DURING CLIMBOUT 17000 FT NR 1 BLD OPEN, NR 2 BLD CLOSED. LIGHT EXTINGUISHED WHILE RUNNING CKLIST FOR STRUT OVERHEAT LIGHT. *S/D* REPLACED DUCT ASSY PER MM 36-00-001-2. OPS AND LEAK CK OK.