What was found
HYD PRESS LOST, BOTH PRESS LIGHT ILLUM. REMOVED AND REPLACED NR 1 T/R AND 2 PUMP CASE DRAIN FILTERS PER IAW MM 29-11-041-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYD PRESS LOST, BOTH PRESS LIGHT ILLUM. REMOVED AND REPLACED NR 1 T/R AND 2 PUMP CASE DRAIN FILTERS PER IAW MM 29-11-041-2.