What was found
VERTICAL STAB NR 7 STR LT IS CHAFED 3 INCHES FRONT OF SLIDING SEAT TRACK. REPAIRED CHAFFED AREA OF VERTICAL FIN STR 7 MID SPAR STA 229 PER SRM 55-30-06 FIG 3 PER FEDEX EA NR 7-5530-54129.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VERTICAL STAB NR 7 STR LT IS CHAFED 3 INCHES FRONT OF SLIDING SEAT TRACK. REPAIRED CHAFFED AREA OF VERTICAL FIN STR 7 MID SPAR STA 229 PER SRM 55-30-06 FIG 3 PER FEDEX EA NR 7-5530-54129.