SDR 0204129986

Service difficulty report · Controller · Doug DC932

Difficulty date
December 14, 2002
Submitted
December 23, 2002
Operation
Air carrier
Aircraft
N986US
Make and model
Doug DC932
Aircraft serial
47480
Aircraft time
76,546 hours, 68,411 cycles
Engine
Pwa JT8D
Part
Controller
Condition
Failed
Location
Cabin Temp
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMB, FLIGHT ATTENDANT REPORTED CABIN RAPIDLY BECAME HOT AND SMELLED HOT. F/O REPORTED RIGHT PACK TEMP HIGH. PACK TEMP REDUCE IN MANUAL OPERATION. FLIGHT RETURNED TO AND LANDED WITHOUT INCIDENT. REPLACED CABIN TEMP CONTROLLER AND RIGHT COALESCER BAG. PERFORMED PACK BURN OUT AND SYSTEM OPERATION CHECKS GOOD.