What was found
DURING DESCENT THE LOWER AFT BODY OVERHEAT LIGHT CAME ON FOR APPROX 2 SECONDS THEN WENT OUT. THIS OCCURRED ONLY 1 TIME AND THE SYSTEM TESTED NORMALLY. ALL OTHER AIRCRAFT SYSTEMS/INDICATIONS NORMAL. INSPECTED AND FOUND SENSE LINE AT STATION 1243 LT SIDE OF AFT STAIR WELL TOUCHING BLEED AIR SUPPLY LINE. REPOSITIONED LINE WITH NEW CLAMPS OPERATIONALLY CHECK GOOD. ALL WORK DONE IAW B727MM 26-14-00, OK FOR SERVICE.