What was found
STUD SHEARED AT RIGHT O/B FLAP O/B FWD HINGE HALF AT AFT SPAR ATTACHMENT LWR O/B ATTACH POINT. REMOVED AND REPLACED ALL 4 STUDS AT AFT SPAR IAW 57-41-01-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STUD SHEARED AT RIGHT O/B FLAP O/B FWD HINGE HALF AT AFT SPAR ATTACHMENT LWR O/B ATTACH POINT. REMOVED AND REPLACED ALL 4 STUDS AT AFT SPAR IAW 57-41-01-2.