What was found
CORROSION ON UPPER SURFACE OF FLOORBEAM AT BS 328, LBL 3, WL 208. REMOVED CORROSION FOUND TO BE OUT OF LIMITS CUT OUT DAMAGE AREA. FABRICATED REPAIR ANGLES, AND FILLERS, & INSTALLED IAW SRM 51-30-2, 51-30-5, 51-30-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON UPPER SURFACE OF FLOORBEAM AT BS 328, LBL 3, WL 208. REMOVED CORROSION FOUND TO BE OUT OF LIMITS CUT OUT DAMAGE AREA. FABRICATED REPAIR ANGLES, AND FILLERS, & INSTALLED IAW SRM 51-30-2, 51-30-5, 51-30-8.