What was found
MDCC FLOOR SEAT TRACK FLANGE FOUND WITH CORROSION AT STA 1521, LBL 8. TRIMMED CORRODED FLANGE AT STA 1521, LBL 8 IAW SRM. NON DESTRUCTIVE TESTING CARRIED OUT AT TRIMMED AREA IAW DAC NDT SPM. FAB FILLER AND STRAP IAW SRM. INSTALLED IAW SRM.