MDCC FLOOR SEAT TRACK FOUND WITH CORROSION AT STA 585 - 685, X=-107.25. TRIMMED DAMAGED AREA ON FLANGE AT STA 653 RBL 107.25 IAW SRM. FABRICATED FILLER AND STRAP IAW SRM. INSTALLED FILLER AND STRAP IAW SRM.