What was found
SMOKE/ELEC FUMES FROM MASTER CAUTION ANNUNCIATOR PANEL ON CAPTAINS SIDE. STOPPED AFTER 2 MINUTES.FOUND GLARESHIELD FLOURESCENT TUBE NEAR CAPTAINS MASTER CAUTION PANEL DISPLACED FROM SOCKET. THIS ARCED WITH SLIGHT MOVEMENT. CLEANED SOCKET AND TUBE AND RESEATED AND SECURED. OPS CHECKED GOOD.