What was found
CORROSION ON STR 28R, BS 480-484, WL 150, INBOARD SIDE. REMOVED CORROSION FROM STR 28R AT B.S 480+4 INCH, FOUND TO BE OUT OF LIMITS. FABRICATED, ALODINED AND PRIMED REPAIR PARTS, AND INSTALLED IAW SRM 51-10-4, 53-10-1, 53-10-3, 51- 30-2 AND MM 51-20-151-7.