What was found
CORROSION ON 950D FLOORBEAM UPPER FLANGE UPPER AND LOWER SURFACES RBL 25, LBL 25, WL 208. REMOVED CORROSION FROM FLOORBEAM BS 950D, RBL 10.5, FOUND OUT OF LIMITS IAW SRM 53-10-1. CUT OUT DAMAGED SECTION OF UPPER CHORD BS 950D LBL 37-RBL 37. FABRICATED REPAIR PARTS, INSTALLED IAW SRM 53-10-8 FIG 3, SRM 51-30-2 PG 13 &14.