What was found
LT WING, LOWER ACCESS CUTOUT FOR PANEL 550GB. TWO SCREW HOLES FOR PANEL HAVE DAMAGED EDGES. REMOVED ANCHOR NUTS TO ACCESS DAMAGED HOLES. REMOVED DAMAGED AREA AND REAMED HOLES TO 0.495 AND 0.467. ENSURED CLEANED HOLES ARE CRACK FREE BY HFEC IAW NTM 51-10-01. FABRICATED 2 BUSHINGS FROM 2024T3 AND FREEZE INSTALLED. REAMED BOTH HOLES TO FINAL DIA. OF 0.312 AND PROTECTED AFFECTED AREA IAW SRM A310 SRM 51-23-00. REINSTALLED ANCHOR NUTS. ALL WORK COMPLETED IAW RAS 0288/2003 AND EA 6-5710-68295 DATED 02-13-2003.