What was found
CORROSION ON FLOOR SUPPORT UNDER NUTPLATE BS 1165-1166, LBL 7, WL 155. REMOVED CORROSION ON FLOOR SUPPORT UNDER NUT PLATE BS 1165-1166, LBL 7, WL 155. AN AREA OF 1 X 2 INCHES. ORIGINAL THICKNESS .063 INCH. REMAINING .050 INCH OUT OF LIMITS PER SRM 53- 10-1. REMOVED FLOOR SUPPORT BS 1166-1155. FABRICATED REPAIR PARTS PER SRM 53-10- 5 & SR 27-53-039. ALODINED & PRIMED PER SRM 51-10-2. INSTALLED PARTS PER SRM 51-30-2.