What was found
BS 1050 FRAME PUNCTURED BY FLOOR PANEL FASTENER, RBL 21, WL 156. BS 1050 FRAME RBL 21 W/L 156 FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED & INSTALLED REPAIR DOUBLER AT BS 1050, RBL 21, WL 156 IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1050 FRAME PUNCTURED BY FLOOR PANEL FASTENER, RBL 21, WL 156. BS 1050 FRAME RBL 21 W/L 156 FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED & INSTALLED REPAIR DOUBLER AT BS 1050, RBL 21, WL 156 IAW SRM 51-30-2.