What was found
REPEAT WRITEUP. ENG NR 1 STRUT OVERHEAT LIGHT ILLUMINATED ON CLIMBOUT. COMPLIED WITH RED TABS AND LIGHT EXTINGUISHED WHEN NR 1 BLEED AIR SWITCH CLOSED AND LEFT, PACK TURNED OFF. REMAINED OFF FOR REST OF FLIGHT. INSPECTED NR 1 STRUT OVHT. DETECTOR SENSOR CONNECTORS NO DAMAGE NOTED, CLEANED CONNECTOR ENDS WITH CONTACT CLEANER. AFTER READING WIRING DIAGRHAM ENCH ENG. STRUT HAS A SEPARATE CONTROL UNIT INSIDE THE FIRE AND OVHT.DET. MODULE REMOVED AND REPLACED THE FIRE AND OVHT. DET. MODULE UNIT IAW MM 26-14-000-0 SYS OPS CK GOOD IAW MM 26-14-00-5.