Service difficulty report · Pump · Doug MD11

Difficulty date
June 30, 2003
Submitted
July 1, 2003
Operation
Air carrier
Aircraft
N619FE
Make and model
Doug MD11
Aircraft serial
48770
Aircraft time
24,392 hours, 5,555 cycles
Part
Pump
Condition
Failed
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
M, J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HYD PUMP 1R OFF DISPLAYED DURING CRUISE AT FL280. PUMP 1R FAULT LIGHT ON HYD OVERHEADD ILLUMINATED. HYD SYS 1 TEMP INDICATED 94 DEG C. SUBSEQUENTLY HYD 1 OFF ALERT AND NR 2 AUTOPILOT DISCONNECT. RETURNED TO RPLB. TEMP DECREASED TO 79 DEG C, WHEN ON APPROACH. SLATS EXTENDED, BOTH PUMPS ON, NORMAL FLAP AND GEAR EXTENSION. NO A/P WITH LOWER YAW DAMP INOP. FACT: REMOVED AND REPLACED 1L AND 1R EDP AND CASE DRAIN FILTERS. FLUSHED HYD SYSTEM. OP/LEAK CHECKS GOOD ON ENGINE RUN.