What was found
FRAME DENTED BS 520 STR 24L. INSPECTED DENTS AT BS 520, STR 24L. FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, FIG 1, DETAIL II, NOTE [S]. CUT OUT AND REPAIRED DAMAGE PER SRM 51-40-3, FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME DENTED BS 520 STR 24L. INSPECTED DENTS AT BS 520, STR 24L. FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, FIG 1, DETAIL II, NOTE [S]. CUT OUT AND REPAIRED DAMAGE PER SRM 51-40-3, FIG 1.