What was found
DAMAGED FASTENER HOLE ON FRAME AT BS 1070, LBL 22, WL 152. DAMAGED FASTENER HOLES ON FRAME AT BS 1070, LBL-22, WL-152 FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, CUT OUT DAMAGED MATERIAL AND REPAIRED IAW SRM5 1-40-3, FED- EX EA 7-5310-54913.