As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
VERTICAL STAB LT TEE SUPPORT IS CHAFED WHERE PANEL 8603 LWR ATTACHMENT ANGLE, ATTACHES TO THE PANEL SUPPORT. CUT OUT DAMAGED AREA 3 X 1 INCH ON LT VERTICAL STAB SUPPORT AT PANEL 9603'S AFT ATTACH ANGLE MOUNT HOLE. FABRICATED AND INSTALLED REPAIR IAW SRM 55-30-6 FIG 3.