HYD AUXILIARY PUMP NR 2 ELECTRICAL CONNECTOR FOUND ELECTRICALLY SHORTED AND ARCING DAMAGED. AUX ELEC PUMP REMOVED AND REPLACED AS PER AMM 29-21-01. ELECTRICAL: REMOVED AND REPLACED B1-624 RCCB AS PER STANDARD WIRING PRACTICE. REMOVED AND REPLACED NR 2 HYD PUMP ELECT CONNECTOR AS PER STANDARD WIRING PRACTICE. NR 2 PUMP ELECT WIRING INSULATION CHECKED, FOUND SATISFACTORY. PUMP OPS CHECK CARRIED OUT AS PER MM 29-21-01-5, FOUND SATISFACTORY.