What was found
CORROSION ON BEAM BS 269, LBL 3, WL 208. REMOVED CORROSION IN A 3.0 X 3.0 AREA, .050 MATERIAL LOSS FROM AN ORIGINAL THICKNESS OF .125 FOUND TO BE OUT OF LIMITS PER SRM 53-10-1 FIG. 1. REMOVED FE'S SEAT TRACK AT BS 268, REMOVED 4EA FLOOR SUPPORTS AT BS 266-276, LBL 3,RBL 3,RBL 14, AND BS 260-276, LBL 8, WL 208. REMOVED BEAM UPPER CHORD, FABRICATED CHORD FROM P/N 65-17588-66, ALOODINED, PRIMED, RESTORED SURFACE FINISH, INSTALLED REPLACEMENT CHORD AT BS 269, LBL 8-RBL 21, WL 208. REINSTALLED FLOOR SUPPORTS, INSTALLED FASTENERS IN FLOOR WEB REMOVED FOR BEAM REMOVAL, REINSTALLED F.E.'S SEAT TRACK. ALL WORK DONE PER SRM 51-30-2, 51-10-2, 51-30-5.