As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT WING OB FLAP IB 4 EACH FITTINGS ATTACH STUDS HAVE PITTING CORROSION AND FLAT THREATS. CLOSING ACTION ON 10/03/03.ON N/R N01201. REMOVED AND REPLACED LT FLAP MOUNT STUDS HINGES IAW M/M 57-41-01-2. ENCAPSULATED (2) BOTTOM MOUNT STUDS IAW M/M 57-41- 01-2, AND E.A 8-5750-72304.