What was found
CORROSION (C53-224-01, 3) FLOORBEAM BS 1050, LBL 27, WL 208. BLENDED CORROSION ON TOP CHORD OF FLOORBEAM IN A 1 X 1 X .029 INCH FOUND TO BE OUT OF LIMITS PER SRM 53-10-1 FIG 4. REMOVED TOP OF CHORD FROM LBL 19 TO 30.5 AND INSTALLED REPAIR PER SRM 53-10-8 FIG 1.