What was found
FWD LWR CARGO FRAME IS DENTED AT STA 560 STR 24 LT. REMOVED DAMAGE AREA AT FRAME IN AREA 1 X 2, AT BS 560, STR 24 LT. FABRICATE THE DOUBLER MADE FROM 7075-T6 0.063, AND INSTALLED REPAIR DOUBLER IAW SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD LWR CARGO FRAME IS DENTED AT STA 560 STR 24 LT. REMOVED DAMAGE AREA AT FRAME IN AREA 1 X 2, AT BS 560, STR 24 LT. FABRICATE THE DOUBLER MADE FROM 7075-T6 0.063, AND INSTALLED REPAIR DOUBLER IAW SRM 51-40-3.