What was found
WHILE WORKING CARD NR N01362, FOUND CORROSION ON FLOORBEAM STA 312, RBL 14, WL 208. FLOORBEAM AT BS 312 WAS OUT OF LIMITS. REMOVED DAMAGED BEAM & REPAIRED. INSTALLED NEW SECTION PER SRM 53-10-8 FROM RBL 14 TO LBL 65.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE WORKING CARD NR N01362, FOUND CORROSION ON FLOORBEAM STA 312, RBL 14, WL 208. FLOORBEAM AT BS 312 WAS OUT OF LIMITS. REMOVED DAMAGED BEAM & REPAIRED. INSTALLED NEW SECTION PER SRM 53-10-8 FROM RBL 14 TO LBL 65.