What was found
WHILE WORKING FOUND UPPER FLANGE OF FRAME BS 1090 LBL 18 WL 150 TO BE TRIPLE HOLED. REMOVED DAMAGE ON UPPER FLANGE OF FRAME BS 1090, LBL 18, WL 150. INSTALLED NEW FABRICATED DOUBLER FOR FRAME AT BS 1090, WL 150, LBL 18 IAW SRM 51-40-3.