What was found
WHILE WORKING FOUND UPPER FLANGE OF FRAME BS 1070 LBL 18 WL 150 TO BE DOUBLE HOLED. REMOVED DAMAGE ON FRQME QT BW 1070, LBL 18, WL 150 UPPER FLANGE. INSTALLED NEW FABRICATED DOUBLER FOR FRAME AT BS 1070, WL 150, LBL 18 IAW SRM 51-40-3.