As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING FLAP RETRACTION NR 3 KRUEGER FLAP FAILED TO RETRACT, RECYCLED WITH NO CHANGE. NO RESTRICTION NR 3 KRUEGER FLAP HAS THE RETRACT SWITCH JUMPER INSTALLED. RAN FLAPS THRU, FWD & AFT INDICATOR LIGHTS CK NORMAL. REPLACED NR 3 KRUEGER FLAP INDICATION SWITCH REF 27-82-001-4. GROUND OPS CK NORMAL AT THIS TIME. JUMPER INSTALLED BACK IN F/E DESK. CLEARS CONTROL NR 182339. A/C OK FOR SERVICE.