What was found
CORROSION 1) NR 1 CARGO DOOR CUTOUT FWD FRAME BETWEEN WEB AND I/B CHORD STA 560 RBL 26 WL 166. CORROSION NR 1 CARGO DOOR CUT OUT FWD FRAME BETWEEN WEB AND I/B CHORD STA 560, RBL 26, WL 166, FOUND TO BE OUT OF LIMITS PER SRM 53-10-1. REPAIRED DAMAGE AREA PER EA 7-5310- 70612.