What was found
CORROSION ON SHEAR TIE AT BS 500 STR 27 LT WL 148. BLENDED CORROSION ON SHEAR TIE AT BS 500 STR 27 LT WL 148 PER SRM 51-10-1. BLEND AREA WAS 2X1INCHES, ORIGINAL THICKNESS WAS .063. 100 PERCENT MATERIAL WAS REMOVED. REMOVED DAMAGED SHEAR TIE, BS 500, STR 27, WL 148 AND FABRICATED, LOCATED, DRILLED, ALODINED, PRIMED, PAINTED, AND INSTALLED NEW SHEAR TIE PER SRM 51-30-5, 51-30-6, 51-10-2, 51-30-2 AND FED EX MM 51-20-151-7